![Takex PXB-100ATC Instruction Manual Download Page 22](http://html1.mh-extra.com/html/takex/pxb-100atc/pxb-100atc_instruction-manual_3391320022.webp)
ALARM LED
9-5
LED is on according to signal output (Both AT output, HF output)
Alarm LED
Response time
(AT output)
Signal output
Environmental output
Beam power
Modulation frequency
Synchronized timing
Setting
Sound check
Master or slave
Whether to set on
transmitter or receiver
Both transmitter
and receiver
Transmitter only
Receiver only
0.1
s
0.2
s
0.3
s
0.5
s
N.O.
N.C.
N.O.
N.C.
Master
Slave
Check the various functions according to the table as below
<<Caution>>
Sensitivity attenuation LED
Setting details
Even if the beam power recover immediately, an environmental output is issued for at least 5sec.
<<Caution>>
1CH
2CH
3CH
4CH
H
L
A
B
ON
OFF
* Only installed on the receiver
* Only installed on the receiver
* Only installed on the receiver
* Only installed on the receiver
PROGRAMMABLE AGC(AUTO GAIN CONTROL) FUNCTION
9-3
EXTERNAL ENVIRONMENT DIAGNOSTIC FUNCTION
9-4
LIGHT SENSITIVITY SIGNAL FUNCTION
9-6
FUNCTION SETTING CHECK
9-7
ALIGNMENT WIRELESS CHECKER CONNECTION FUNCTION
9-8
When the beam power decreases in harsh environment by dense fog, heavy rain. This is a function to increase the receiving
sensitivity temporarily and to stabilize operation. The receiver adjusts this function to start or to stop automatically
depending on beam power from transmitter.
When the Programmable AGC works, the beam power level which already decreased recovers to certain power level and is
maintained.
When the Programmable AGC works, the environmental signal is issued, and it is continuing to monitoring the beam
power level while the environmental signal is issued.
When either upper beam or lower beam power decrease, the Programmable AGC works and the environmental signal is
issued.
When both upper beam and lower beam power recover to stable level, the Programmable AGC function and the
environmental output stop automatically.
In order to operate the Programmable AGC function correctly, it is necessary to set up
"Auto Gain Lock" function correctly
The margin of sensitivity is maintained even if there is a sudden worsening in weather conditions.
This function outputs a notification before a warning is output as an environmental output when such impairments
as fog or heavy rain occur.
If such impairments continues for 20sec, an environmental output is issued.
This lights when there is an insufficient level of infrared light received by the
receiver, and it is judged that there is insufficient margin of sensitivity, and to
inform you that adjustments are required.
: Light on
: Off
: Light on
: Off
Self checking
* Installed on the transmitter and the receiver
Flashing
Off
By connecting an alignment
wireless checker (sold separately),
it is possible to transmit data
bidirectionally, check the monitor
output voltage of the receiver from
the transmitter, and simultaneously
switch the optical axis light
obstruction.
Bidirectional communication
Manual checking
Light on
Light on
Flashing
Off
Bidirectional communication
* Alignment wireless checker : ER-02
When using the wireless checker, please set
Auto Gain Lock switch "OFF" certainly.
22