Takex PXB-100ATC Instruction Manual Download Page 20

OPERATION CHECK

8

Be sure to perform an operation check after the optical axis adjustment.

Light on

Transmitter

Receiver

Receiver

After 5 seconds

"Pi-"  :   PASS
"PiPiPi......"  :   FAIL

Auto-gain Lock switch

1

2

3

After the optical adjustment is completed, set Auto Gain Lock switch to [ON] under 
the light beam reception condition, and wait for approximately 5 seconds.
During this period, do not shield the optical axis.
A one-time short beep sound [Pi-] shows that the auto gain lock is completed 
correctly.
(After the auto gain lock, the upper and lower LEDs light off.)

Obstruct the sensor beams near the sensor or the center of 
the detection line and check that an alarm can be output 
correctly.

After the auto gain lock is completed correctly, mount the 
covers in the transmitter and receiver and secure them 
using the cover lock screws.

If the sound check switch is set to ON, after the auto gain lock has 
been completed normally, the walk test mode is activated for 5 
minutes. The beep sound is generated in synchronization with the 
alarm output.
The alarm LED lights up according to the alarm output.

After the auto gain lock is completed correctly, the walk test mode is activated for 5 
minutes regardless of whether the cover is mounted or not. During the walk test 
mode, the beep sound is generated when the alarm LED lights on by the alarm 
output. After approximately 5 minutes has elapsed, the walk test mode ends. Even if 
Auto Gain Lock switch is not set to ON, close the cover to activate the walk test mode 
for 5 minutes.

The intermittent beep sound like “PiPiPi........” shows that the beam reception 
volume is not enough. In this case, the LED on the side of the insufficient 
reception volume blinks. Set Auto Gain Lock switch to [OFF], and adjust the 
optical axis again.
In the multi-level protection, when the light enters from other units than the 
opposing transmitter, turn off the power of the other transmitter to stop 
transmitting the light beam, then set Auto Gain Lock switch to [ON].

<<Caution>>

When the cover is mounted, the transmitter is 
automatically set to [Transmit in both upper and lower 
sections], and the receiver is automatically set to 
[Reception authorized in both upper and lower sections].

<<Caution>>

An alarm is output

Light on

The sensor beams are 
not obstructed

Light entrance due to 
wrap around of the beams

(Due to light entrance caused 
by reflection)

4

Turn off the power to the 
transmitter and check that 
an alarm is output.

Change the height or location of the sensor so 
that the light on the detection line can be 
obstructed completely.

Change over a channel or synchronized timing.

Readjust the optical axis, and move the direction 
of the optical axis away from the reflection surface 
within the allowable range.
(Perform this for both the transmitter and receiver)

Spill-over light entrance

No alarm is output

* It results from the same channel and the same synchronized timing settings.

If no alarm is output

Beep
(high pitch
beep)

Shield the light

Shield the light

Light enters

Light enters

Spill-over

No alarm is output

No alarm is output

Wrap around

Walls, etc.

Light entrance due to beam wraparound

Spill-over light entrance

Transmitter

Transmitter

Transmitter

Transmitter

Receiver

Receiver

Receiver

Receiver

In using the environmental output, confirm 
that the environmental output is generated 
when the optical axes in both the upper and 
lower sections are shielded for 20 seconds or 
more.

ON

20

Bleep
(High-pitched
tone)

Summary of Contents for PXB-100ATC

Page 1: ...lly detects the objects and issues a signal only by blocking each beam AT output OR gated by upper and lower beam HF output AND gated By synchronizing the timing of transmitting and receiving beam the...

Page 2: ...TIONS EXTERNAL DIMENSIONS OPTIONAL PRODUCT COMPONENTS 1 1 1 2 1 3 OPERATING PRECAUTIONS 2 1 BEFORE USE 3 1 3 2 3 3 3 4 3 5 INSTALLATION METHOD 4 1 4 2 INITIAL SETTING 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 1...

Page 3: ...PPER LOWER CHANGEOVER FUNCTION Transmission LED Upper lower Light reception authorization LED Upper lower Red Beam power switch Factory set H Transmitter channel changeover swicth Factory set 1CH Alar...

Page 4: ...s to be observed for safe operation of this device by classifying them into the following categories As these are important be sure to read and strictly observe them Warning Caution Description of the...

Page 5: ...adverse effects of the environment resulting in a malfunction If the optical axis center of the light beams is aligned correctly a detection line with sufficient margin of sensitivity is formed 180 90...

Page 6: ...cy channel of the infrared beam signal There are four channel from 1CH to 4CH A signal emitted from the synchronized output of the master which is the reference signal to determine the timing for tran...

Page 7: ...eiver to the same channel Set the transmitter and receiver to the same syncronized timing Set the transmitter as a master Connect the synchronized units by wire Connect between synchronized unit Set a...

Page 8: ...ly installed 3CH 3CH A Slave B Slave 1 s t 2 n d 2CH 2CH A Slave B Slave 1 s t 2 n d 2CH 2CH A B 1 s t 2 n d 4CH 4CH A B 1 s t 2 n d 3CH 3CH A B 1 s t 2 n d 3CH 3CH A Slave B Slave 1 s t 2 n d 3CH 3CH...

Page 9: ...UP Y UIF TFOTPS CPEZ UP UIF JOTUBMMBUJPO QMBUF t 1MBDF UIF JOTUBMMBUJPO QMBUF JO QPTJUJPO UIFO FOTVSF UIBU UIF TQBDF TIPXO CZ UIF EPUUFE MJOFT JT BMMPDBUFE CFGPSF NBSLJOH UIF QPTJUJPOT PG UIF TDSFXT P...

Page 10: ...PPG BOE EVTU QSPPG DPVOUFSNFBTVSF GPS UIF TFOTPS FYUFSJPS About the grommet t SJMM B QJMPU IPMF PG NN PO UIF QPMF BOE then tap an M4 hole PUF F FYUSFNFMZ DBSFGVM XIFO drilling a pilot hole on the pole...

Page 11: ...t neighboring number Factory set A 250ft 75m or less 250ft 75m 330ft 100m Set the transmitter and the receiver to the same channel MASTER SLAVE SELECTION ALARM OUTPUT SWITCH ENVIRONMENTAL OUTPUT SWITC...

Page 12: ...sponse time is 0 05s 2 In case HF output is selected Signal is issued only when both of upper and lower beam is shielded simultaneously The response time is 0 05s Only installed on the receiver AT out...

Page 13: ...of the same group by synchronized wiring Select one transmitter as a master all the others are as slave One master can connect maximum 7 slaves Transmitter 3 Receiver 4 in one synchronized wire group...

Page 14: ...C N C Env Alarm Tamper Env N C N C N C 1st 1st 2nd 1st 2nd 3rd 4th 2nd Master Slave Slave Slave Master Slave Alarm Tamper Env N C N C N C Master PXB 100HF PXB 100ATC Control panel Control panel Transm...

Page 15: ...plete optical axis adjustment Note Sequence of adjustment When the view finder is looked closely view appears as the diagram on the right Adjust the angle so that the target color appears in the cente...

Page 16: ...d Shows lower reception level Both of upper lower beam authorized Show the reception level of the less one To maintain the most suitable margin of sensitivity for the protection distance and reduce th...

Page 17: ...Different channel between transmitter and receiver The unit is receiving disturbance from other unit Improper sighting Set the same channel Set the channel as different number Connect the synchronizi...

Page 18: ...ransmitter and receiver 3 Fine adjust the lower level optical axis 1 Press the upper lower changeover switch on the transmitter to select Only transmit from lower 2 Press the upper lower changeover sw...

Page 19: ...rusion alarm system Note For detailed operation procedure of the alignment wireless checker refer to the instruction manual for the alignment wireless checker ER 02 More than 2 2 V DC 2 0 to 2 2V DC L...

Page 20: ...ase the LED on the side of the insufficient reception volume blinks Set Auto Gain Lock switch to OFF and adjust the optical axis again In the multi level protection when the light enters from other un...

Page 21: ...s ON the beep sounds to show the conditions Provided the units are used within the maximum rated protection distance this function is used to automatically set the optimum margin of sensitivity for th...

Page 22: ...GC works the environmental signal is issued and it is continuing to monitoring the beam power level while the environmental signal is issued When either upper beam or lower beam power decrease the Pro...

Page 23: ...e detection response time 1 Connect the power source 2 Check again 3 Press the upper lower changeover switch Transmitter LED does not light cover is open Reception authorization LED does not light on...

Page 24: ...During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products original date of shipmen...

Reviews: