Takex PXB-100ATC Instruction Manual Download Page 1

(9) DRIP-PROOF HOUSING

Prevents rain and snow from streaming down 
the front side of housing, helping to avoid false 
alarm. 

Main Features 

Coverage of light beams 

Upper detection line 

Lower detection line 

Receiver 

Transmitter  

Keeps birds and small animals away from the
sensor, helping to reduce false alarms. 

The vivid color of the internal structure can be
recognized easily from the far end in the beam
alignment procedure.
The color differs between a transmitter and a 
receiver which helps easy installation and
checking.  

Enables easy and accurate beam alignment.
(Sold separately)  

Minimizes the damage caused by induced 
lightning through wiring. 

Vertically ±20°compared with previous version. 
It may adapt to the slope installation flexibly

Enables better and clear view for easy beam
alignment. 

Double modulated beams are designed to distinguish the true 
beam signal from accidental or deliberate interference from 
sunlight, car headlights and other artificial light sources.
This increases the reliability in the outdoor security system.

The beam power is 100 times of  the minimum requirement.
The beam distance is 10 times of the described specification.
This high power beam also realizes the reliability against the
harsh conditions like fog, snow, heavy rain.   

IP65 rated, with anti-insect bushing and special wading.

Thank you for purchasing this product.
Read this instruction manual before using the product to make sure that you use it correctly.

&

HF

AT

Upper and lower beam individually detects the objects and
issues a signal only by blocking each beam.

AT output : OR-gated by upper and lower beam.
HF output : AND-gated.

By synchronizing the timing of transmitting and receiving
beam, the stacking system will be more reliable.

PHOTOELECTRIC BEAM SENSOR

Instruction Manual

(1) ANTI-CRAWL DETECTION

(2) AT . HF SEPARATE OUTPUT

1

2

3

4

(3) SYNCHRONIZED HIGH POWER BEAM

(5) QUAD HIGH POWER BEAM

(6) ECOLOGY

(7) INSECT/WATER PREVENT

(8) ANTI-BIRD STOPPER

(10) DUAL RING SIGHT

(11) TARGET COLOR

(12) INCREASED RANGE 
      ADJUSTMENT ALLOWANCE

(13) WIRELESS ALIGNMENT CHECKER

(14) LIGHTNING PROTECTION

(4) DOUBLE MODULATION

RoHS adapted - Environment friendly.  Free from Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated 
biphenyl, Polybrominated diphenyl ether.  

Anti-Crawl and Anti-Corrosion 
PXB-100ATC : OUTDOOR 330ft (100m)

This device is an opposed type photoelectric beam sensor that consists of 
a photo transmitter that transmits infrared light, and a photo receiver 
for the transmitted light, as shown in the illustration on the right.
The infrared light transmitted from the transmitter expands in a cone 
shape, while the light beams enter the receiver.
The straight line that connects the transmitter with the receiver is the 
detection line.
This model is designed to prevent a crawling intrusion to coverage area 
by means of OR-gated detection in addition to AND-gated detection.

In order to ensure that the detection line has sufficient margin of 
sensitivity, adjust the direction of the light beams before placing the 
system into operation. Providing sufficient margin of sensitivity reduces 
the occurrence of malfunction caused by dense fog, heavy rain, frost, 
snow, and other such weather conditions. 

1

Summary of Contents for PXB-100ATC

Page 1: ...lly detects the objects and issues a signal only by blocking each beam AT output OR gated by upper and lower beam HF output AND gated By synchronizing the timing of transmitting and receiving beam the...

Page 2: ...TIONS EXTERNAL DIMENSIONS OPTIONAL PRODUCT COMPONENTS 1 1 1 2 1 3 OPERATING PRECAUTIONS 2 1 BEFORE USE 3 1 3 2 3 3 3 4 3 5 INSTALLATION METHOD 4 1 4 2 INITIAL SETTING 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 1...

Page 3: ...PPER LOWER CHANGEOVER FUNCTION Transmission LED Upper lower Light reception authorization LED Upper lower Red Beam power switch Factory set H Transmitter channel changeover swicth Factory set 1CH Alar...

Page 4: ...s to be observed for safe operation of this device by classifying them into the following categories As these are important be sure to read and strictly observe them Warning Caution Description of the...

Page 5: ...adverse effects of the environment resulting in a malfunction If the optical axis center of the light beams is aligned correctly a detection line with sufficient margin of sensitivity is formed 180 90...

Page 6: ...cy channel of the infrared beam signal There are four channel from 1CH to 4CH A signal emitted from the synchronized output of the master which is the reference signal to determine the timing for tran...

Page 7: ...eiver to the same channel Set the transmitter and receiver to the same syncronized timing Set the transmitter as a master Connect the synchronized units by wire Connect between synchronized unit Set a...

Page 8: ...ly installed 3CH 3CH A Slave B Slave 1 s t 2 n d 2CH 2CH A Slave B Slave 1 s t 2 n d 2CH 2CH A B 1 s t 2 n d 4CH 4CH A B 1 s t 2 n d 3CH 3CH A B 1 s t 2 n d 3CH 3CH A Slave B Slave 1 s t 2 n d 3CH 3CH...

Page 9: ...UP Y UIF TFOTPS CPEZ UP UIF JOTUBMMBUJPO QMBUF t 1MBDF UIF JOTUBMMBUJPO QMBUF JO QPTJUJPO UIFO FOTVSF UIBU UIF TQBDF TIPXO CZ UIF EPUUFE MJOFT JT BMMPDBUFE CFGPSF NBSLJOH UIF QPTJUJPOT PG UIF TDSFXT P...

Page 10: ...PPG BOE EVTU QSPPG DPVOUFSNFBTVSF GPS UIF TFOTPS FYUFSJPS About the grommet t SJMM B QJMPU IPMF PG NN PO UIF QPMF BOE then tap an M4 hole PUF F FYUSFNFMZ DBSFGVM XIFO drilling a pilot hole on the pole...

Page 11: ...t neighboring number Factory set A 250ft 75m or less 250ft 75m 330ft 100m Set the transmitter and the receiver to the same channel MASTER SLAVE SELECTION ALARM OUTPUT SWITCH ENVIRONMENTAL OUTPUT SWITC...

Page 12: ...sponse time is 0 05s 2 In case HF output is selected Signal is issued only when both of upper and lower beam is shielded simultaneously The response time is 0 05s Only installed on the receiver AT out...

Page 13: ...of the same group by synchronized wiring Select one transmitter as a master all the others are as slave One master can connect maximum 7 slaves Transmitter 3 Receiver 4 in one synchronized wire group...

Page 14: ...C N C Env Alarm Tamper Env N C N C N C 1st 1st 2nd 1st 2nd 3rd 4th 2nd Master Slave Slave Slave Master Slave Alarm Tamper Env N C N C N C Master PXB 100HF PXB 100ATC Control panel Control panel Transm...

Page 15: ...plete optical axis adjustment Note Sequence of adjustment When the view finder is looked closely view appears as the diagram on the right Adjust the angle so that the target color appears in the cente...

Page 16: ...d Shows lower reception level Both of upper lower beam authorized Show the reception level of the less one To maintain the most suitable margin of sensitivity for the protection distance and reduce th...

Page 17: ...Different channel between transmitter and receiver The unit is receiving disturbance from other unit Improper sighting Set the same channel Set the channel as different number Connect the synchronizi...

Page 18: ...ransmitter and receiver 3 Fine adjust the lower level optical axis 1 Press the upper lower changeover switch on the transmitter to select Only transmit from lower 2 Press the upper lower changeover sw...

Page 19: ...rusion alarm system Note For detailed operation procedure of the alignment wireless checker refer to the instruction manual for the alignment wireless checker ER 02 More than 2 2 V DC 2 0 to 2 2V DC L...

Page 20: ...ase the LED on the side of the insufficient reception volume blinks Set Auto Gain Lock switch to OFF and adjust the optical axis again In the multi level protection when the light enters from other un...

Page 21: ...s ON the beep sounds to show the conditions Provided the units are used within the maximum rated protection distance this function is used to automatically set the optimum margin of sensitivity for th...

Page 22: ...GC works the environmental signal is issued and it is continuing to monitoring the beam power level while the environmental signal is issued When either upper beam or lower beam power decrease the Pro...

Page 23: ...e detection response time 1 Connect the power source 2 Check again 3 Press the upper lower changeover switch Transmitter LED does not light cover is open Reception authorization LED does not light on...

Page 24: ...During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products original date of shipmen...

Reviews: