Takenaka System FS5100SPL Instruction Manual Download Page 11

N08A29;11/33 

- 11 - 

5.     Various Settings 

 

(5-1)  Operation mode 

 

  CCD output system ······ SINGLE output 

                                                ( output from single port) 

  Electronic shutter operation mode 

Shutter mode 

No shutter/continuous/asynchronous   

Shutter speed category 

High speed/low speed/pulse width control 

(See the right schematic diagram) 

  Scanning system ········· Normal scan/partial scan 

  Refer  to  the  following  page  (Section  6)  for  the 

specific setting method.   

 
(!)   This  camera  does  not  support  the  asynchronous 

shutter mode for the low speed shutter operation.   

 

Table 5-1. Description of electronic shutter operation modes 

Shutter 
mode 

No shutter 

Electronic shutter is not used. 
Exposure time of imaging device is equivalent to one frame duration.   
Exposure is continuously performed for each frame. 

Continuous shutter 

Repeats exposure regardless of external trigger input (Vinit). 
Repetition pitch is per frame. 

Asynchronous shutter 

Electronic shutter is released each time the external trigger is input (Vinit). 
The permissible shortest repetition pitch is [exposure time + 1 frame duration]. 

Type   

of   

shutter 
speed   

Normal shutter 
(High speed shutter) 

Shutter, the exposure time of which is less than one frame, is used. 
The  shutter  speed  can  be  set  as  a  preset  shutter  speed  at  9  different  levels  both  for  the 
continuous shutter/asynchronous shutter mode.   
(!)  As  for  the  shutter  speed  of  the  conventional  FC  series  cameras,  8  different  levels  for  the 

asynchronous shutter mode.   

Low speed shutter 

The shutter, the exposure time of which is two frames or over, is used. 
(Only for continuous shutter mode) The shutter speed can be set as a preset shutter speed at 9 
different levels.   
(Note) This camera allows this setting only for the continuous shutter mode.   

Pulse width control 

In  case  of  the  asynchronous  shutter  setting  only,  the  shutter,  shutter  speed  of  which 
corresponds to the pulse width (during an effective level) of the external trigger input (Vinit) ,   
is released. 
Shutter speed can be set as nH (n = 1 or larger integer number) in H (horizontal synchronous 
time) unit. 

 

Table 5-2 Description of other operation modes 

Scanning 
system 

Normal scan 

The read out for each frame is conducted by the all pixel readout scanning.   

Partial scan 

The read out for each frame is conducted by the partial readout scanning. 
The vertical width of the longitudinal picture area corresponds to 790 lines at the central portion of 
the image pickup area. 

 

[Terminology] Preset shutter············ This refers to the shutter speed setting other than those specified by the pulse width 

control. More specifically, the shutter speed is preliminarily set by the shutter switch 
positions from  “1”  to  “9”  for  the  continuous  shutter  operation,  or  the shutter switch 
positions  from  “1”  to  “9”  (PWC  (where  pulse  width  operation  mode 
setting)=DISABLED)  or  from  “1”  to  “8”  (PWC  (where  pulse  width  operation  mode 
setting)=ENABLE)  for  the  asynchronous  shutter  operation.  The  shutter  speed  is 
defined in the Table 6-1.   

[Terminology] Pulse width control ····· This  is  the  way  of  setting  or  controlling  the shutter speed  by  the  width  of  the  Vinit 

signal that is externally input in the asynchronous shutter mode. With this camera, 
this is selected by setting as “PWC=ENABLED” in the asynchronous shutter mode 
together with the shutter switch position of “9”.   

 
(!)  With the conventional products, the pulse width operation mode is always enabled when “9” is selected for the shutter 

switch in the asynchrony shutter mode. Carefully note that this camera, however, will be in the preset shutter mode 
when “PWC=DISABLED (prohibited)” is set, even if the shutter switch is positioned at “9”.   

 
[Terminology] High speed shutter ····· This means the shutter of which shutter speed is shorter than 1 frame duration(=1 

vertical synchronous time). The shutter speed is set as a preset fixed length of the 9 
different levels that are determined by the position of the shutter switch (continuous 
shutter and asynchronous shutter). 

[Terminology] Low speed shutter ······ This means the shutter of which shutter speed is longer than 1 frame duration. The 

shutter  speed  is  set  as  a  preset  fixed  length  of  the  9  different  levels  that  are 
determined by the position of the shutter switch (continuous shutter). 

 
(!)  This camera does not support the functions of “low speed/asynchronous shutter”.   
 

 

Electroni c shutter 

o peration mode  

No shutter 

oper ation

 

Elec tr oni c shutter  

operation

 

Shutter  
swi tch  = 0

 

Shu tter switch = 1 to 9

 

As ync hrono us shu tter

 

l ow sp eed 

shutter

 

High speed  

shu tter

 

Preset   

shutte r

 

Pulse  width  

con tr ol

 

Contin uous shutter

 

Hi gh  sp eed 

sh utter

 

Fig. 5-1 Electronic shutter operation modes

 

Summary of Contents for FS5100SPL

Page 1: ...anage the camera properly Keep this manual at hand and reread it whenever you are uncertain about the operation Table of Contents 1 Features 3 2 Outline 3 3 Description of Each Component 4 4 How to Op...

Page 2: ...is manual Note Particulars which require the user s attention are explained Particulars which require the user s close attention in terms of comparison with the conventional products are explained Ter...

Page 3: ...tion of smear The ID information set by the user for each camera can be saved and read out whenever necessary via serial communication link 2 Outline Imaging device Progressive scanning interline OB O...

Page 4: ...ns are shown in the following table Pin arrangement of Camera Link connector MDR 26 Connector Pin No Signal name Twin ax cable assignment Pin No Signal name Twin ax cable assignment 1 Insulated wire P...

Page 5: ...DO6 O PORTA7 PORTC7 DO7 O PORTB0 PORTB4 DO8 O PORTB1 PORTB5 DO9 O Uppermost data PORTB2 3 6 7 O Fixed to L level CC1 Vinit2 I Asynchronous shutter trigger CC2 reserved I Reserved for future products C...

Page 6: ...Procedure for switching to test pattern output 1 Set the mode switch on the rear of the camera to the position 1 2 Apply an upward stroke to the UP DOWN switch lever three times to display the menu o...

Page 7: ...ters of PWC and others See 6 3 How to set operation mode Recommended timing of asynchronous shutter trigger signal Vinit signal for preset shutter pulse width control For the case of preset shutter mo...

Page 8: ...continuous lighting mode the lighting in any time other than this exposure time period would be wasted Since this equipment is capable of outputting strobe signal STRB even in the continuous shutter m...

Page 9: ...emperature data to be returned in response to the RS 232C command RTMP command Numerical conversion required separately Note Carefully note that the temperature data obtained by this monitoring functi...

Page 10: ...s because the MSB is 1 in accordance with 1 The absolute value is 6 because of invert B 11111010 1 B 00000101 1 5 1 6 in accordance with 2 Therefore this value Dt is expressed as 6 in the ordinary sig...

Page 11: ...ng Partial scan The read out for each frame is conducted by the partial readout scanning The vertical width of the longitudinal picture area corresponds to 790 lines at the central portion of the imag...

Page 12: ...tch and mode setting switch it does not require the setting manipulation for the current shutter speed unlike the FC20 series products 5 3 Level setting The level setting is mostly divided into the fo...

Page 13: ...ately saturated into a white level for the output Note The above described unnatural image represents the following states Black and white look inverted at the saturating area The outline of the satur...

Page 14: ...1 As for this camera it must be set to be Pulse width control PWC ENABLED for implementing Pulse width control asynchronous shutter operation When it is set to be Pulse width control PWC DISABLED def...

Page 15: ...orrection 4 Enabled disabled for pulse width control PWC ENABLED DISABLED A to F Program pages from A to F Save Load When the setting of Enabled disabled for pulse width control is not set to be ENABL...

Page 16: ...nal value Offset Saved as the internal value Current settings Save Load Effective even after power off Lost at power off Fig 6 2 Conceptual diagram of saving and loading operations Explanation Correla...

Page 17: ...nchronous shutter mode the repetitive trigger cyclic trigger that is generated inside the camera is automatically input Make sure to set the menu display OFF when the camera is used in the normal stat...

Page 18: ...is to switch between 8 bits and 10 bits for the bit of the image output FORM SINGLE 1ch output is displayed as the CCD output system VSUB The setting value of Vsub voltage substrate voltage of CCD ele...

Page 19: ...ected in CR STRB C Reflected in CR PATTERN Reflected in CR VSUB Saved as numerical value Items requiring manual save into program pages after changed on menu GAIN Saved as numerical value OFFSET Saved...

Page 20: ...ition H 0 to H 9 or H F Where ESPE 1 externally designated number from 0 to 9 designated position is reflected In case of H F external shutter speed in H unit is selected 9 ESP 1 10 ESP 2 11 ESP 3 12...

Page 21: ...r signal Vinit from a user device the operation mode should be set to be Asynchronous Shutter from the beginning before setting the gain and others Note When the pulse width control mode is set for th...

Page 22: ...saved in the program pages from A to F Carefully note that the earlier setting data that were saved by the user are all overwritten and lost Fig 6 4 Setting contents immediately after reading out fac...

Page 23: ...eturning to power on state is received even during the periods when the camera is in the operation modes of Group 2 to D Description of commands 1 Command e Function Initialization of page memory Tran...

Page 24: ...n Command for setting shutter mode and shutter exposure time Transmission from host STX S A or M H or L N or P exposure time ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX tran...

Page 25: ...page A to H ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The factory default is stored in the Page H which will be used when resetting to the default se...

Page 26: ...erating the asynchronous trigger signal The internally generated trigger signal is of negative logic at 100ms 5 The minimum repetition pitch is approx 300ms Only when the trigger signal is input by th...

Page 27: ...15 characters of the ID code character string is read out When an ID code is not set the number of the characters to be returned is 0 20 Command WVSUB Function Command for writing Vsub value CCD subst...

Page 28: ...nd for reading preset Read PRESET Transmission from host STX RPS ETX Return by camera STX ACK RPS PRESET No ETX When gain set value coincides with gain preset value four levels of preset value corresp...

Page 29: ...justed at the capture timing of a capture board the equal definition file to that of the conventional parallel output type can be used for capturing 8 or 10 bit x 2 tap output with 30MHz clock is empl...

Page 30: ...ise specified the time unit of the numbers in the horizontal timing chart is H 3192CLK 3192 x 1 60 00MHz 53 2 S Vertical timing High speed preset shutter asynchronous shutter normal scan Vinit 1 11 3...

Page 31: ...use the impact of 1H difference in exposure time over the signal level is relatively small 2 Synchronize the external trigger signal with the use of the LDV signal of the camera to keep the Vinit phas...

Page 32: ...ower from the equipment and remove the power cable and external connection cables When an abnormal or failure condition is detected immediately stop using this equipment cut off the power supply remov...

Page 33: ...ternal Dimensions External dimensions 21 42 46 9 2 60 26 30 7 4 31 M3 Depth Depth Depth 34 40 13 5 11 11 26 Depth Right and left sides MO DE EXP U D Camera Link I O Same as top side Depth Fig 11 1 FS5...

Reviews: