N11A27;19/37
- 19 -
●
Serial communication baud rate
The serial communication baud rate of this camera is fixed to 9600 bps.
●
Test pattern
It outputs the color bar signal from the camera as the Camera link output and monitor output.
Refer to the section (4-5) “Test pattern display function” for more details.
●
Camera link output bit
The Camera link output format can be switched between Bayer 8bit, Bayer 10bit, Bayer 12bit, and RGB 8bit.
It can be changed by entering an argument to the communication command “H’26” as follows.
H’00 : Bayer 10bit
H’01 : Bayer 8bit
H’02 : Bayer 12bit
H’03 : RGB 8bit
(Note) The monitor output bit cannot be changed.
●
H reset
“H reset” is switched by changing the operation mode of the camera. Refer to (5-1) “Operation mode”. The concrete
example is described in
paragraph “
●
Continuous /asynchronous shutter” of
Table 6-2 [OSD menu1] setting.
●
Vsub voltage
Vsub voltage is appropriately adjusted before shipment, and therefore the setting value should not be changed without a
special reason. If the value is changed by mistake, it can be reset to the factory default by executing “(6-5) Read out of
factory default”.
●
Continuous shutter strobe signal
“
Continuous shutter strobe signal
” is switched by changing the operation mode of the camera. Refer to (5-1)
“Operation mode”. A concrete example is described in paragraph “
●
Continuous /asynchronous shutter” of Table 6-2
[OSD menu1] setting.
●
Vinit2 polarity (CC1)
“Vinit2 polarity” is switched by changing the operation mode of the camera. Refer to (5-1) “Operation mode”. A concrete
example is described in
paragraph “
●
Continuous /asynchronous shutter” of
Table 6-2 [OSD menu1] setting.
●
Operation confirmation buzzer
The confirmation buzzer bleeps when the power is turned on or at the end of serial communication.
The Operation confirmation buzzer can be set to OFF by entering the argument [H’00] to the communication command
“H’28”.