LABEL SETUP
TAL-3100T
The label advance potentiometer resides on top of the TAL-3100T electrical housing. The purpose is to
adjust the stopping position of the label with respect to the peel plate. With the label advance pot turned
all the way counterclockwise the photo eye will stop the applicator instantly when it senses a gap. By
rotating the potentiometer toward the + the applicator will dispense more of the label, and by rotating
the potentiometer toward the – the applicator will dispense less of the label.
1.
To setup the label position, rotate the label advance pot to the – as far as it will rotate.
2.
The goal is to have the applicator stop with a label gap right at the peel edge.
3.
Activate the applicator and watch the dispensing label. If the label does not advance far enough
turn the label advance pot to the +, and repeat until one label is completely dispensed and the
next label is stopped at the peel edge.