TAMP HEAD PLACEMENT
1.
The tamp head placement is crucial for consistent label application.
2.
The vertical gap between the top of peel plate and bottom of the tamp pad
should range from 0”-1/32”. If not loosen the nut at the base of the tamp
cylinder rod
(Shown with red arrow A)
, and unthread to lower the tamp
pad or screw in the rod to raise the tamp pad height.
3.
The horizontal gap between the top of peel plate and the edge of the tamp
pad should range from 0”-1/32”. If not loosen the horizontal mounting
bolts and align to the acceptable range.
ASSIST TUBE PLACEMENT
1.
The air assist tube is used to assist the label out
onto the vacuum pad. As a rule of thumb the
blast patter from this tube should be directed
at a 30° angle onto the vacuum pad. This angle
may vary due to several factors, as a result
different blast angles may have to be
experimented with.