- 8 -
Maintenance
This section describes the procedures for replacing “Rubber pad” on the top of Vacuum pad unit and
for cleaning the vacuum filter used in the Vacuum ejector unit.
WARNING
Make sure that the tester is powered off and unplugged before starting your operation.
Otherwise it could possibly cause bodily injury or mechanical trouble.
Rubber pad replacement
[Operating procedures]
1)
Use your Allen wrench to remove the rubber head by turning the inner fitting counterclockwise
while fastening the vacuum pad unit with a spanner. (Refer to Fig.10)
2)
Separate the inner fitting from the rubber head and replace the rubber pad with a new one.
(Refer to Fig.11)
3)
Install the rubber head again by the Allen wrench while fastening the vacuum pad unit with a
spanner. In this case, make sure not to put any foreign material inside the vacuum pad unit.
[ Fig.10 ]
[ Fig.11 ]
Inner fitting
Allen wrench
Rubber head
Vacuum pad
Vacuum pad unit
Spanner
Rubber pad (10Φ)
(PJG-10-U)