Specifications
195
Conformity Standards
Specification/Models
30-200
30-400
60-100
60-200
500-12
500-24
1000-6
1000-12
Conformity
Standards
LVD
EN61010-1
EMC
EMS EN61326-1
:
(Industrial locations)
EMI EN61326-1
:
(Class A)
Applicable
conditions
・
All cable connecting should be less than 3m and supplied by TAKASAGO, Ltd. as options.
・
It is required to wrap 2T of ferrite clamp, such as RFC-20 manufactured by Kitagawa Industries
or equivalent, around cables while connectors for external control will be used.
・
It is required to wrap 2T of ferrite core, such as GRFC-13 manufactured by Kitagawa Industries
or equivalent, around cables while connectors for isolated external control will be used.
External Control
Specification/Models
30-200
30-400
60-100
60-200
500-12
500-24
1000-6
1000-12
Output
Voltage
Control
External Resistance
0~10kΩ (B, C Curve), 0~
Ω (A Curve)
External Voltage
0~10V DC
External Voltage
(Isolated)
0 to 10V DC only for isolation-option-featured type "model name with I"
Output
Current
Control
External Resistance
0~10kΩ (B, C Curve), 0~
Ω (A Curve)
External Voltage
0~10V DC
External Voltage
(Isolated)
0 to 10V DC only for isolation-option-featured type "model name with I"
Output ON/OFF Control
Normal
Can be controlled at external contact or photocoupler
Isolated
Usable by external contact or photocoupler only for isolation-option-featured type "model name with I"
Input Cut-Off Control
Normal
Can be controlled at external contact or photocoupler
Isolated
Usable by external contact or photocoupler only for isolation-option-featured type "model name with I"
Voltage Monitoring
Output
Normal
For rated output voltage, 10V DC output (non-isolated) accuracy: 0.5% ±
10mV
Isolated
Only for isolation-option-featured type "model name with I", 10V DC output (isolated) accuracy: 0.5% ±
10mV for rated output voltage
Current Monitoring
Output
Normal
For rated output current, 10V DC output (non-isolated) accuracy: 1.0% ±
10mV
Isolated
Only for isolation-option-featured type "model name with I", 10V DC output (isolated) accuracy: 1.0% ±
10mV for rated output voltage
Status Output
The following status and alarm output with open collector isolated by photocoupler.
CV (Constant Voltage)
CC (Constant Current)
P-ON (Input Voltage Normal)
LEVEL1_ALM (OVP, OCP)/ OUTPUT ON/OFF STS
LEVEL2_ALM (Group Alarm)
Summary of Contents for HX-S-G4 Series
Page 157: ...Special Loads 157 This page is blank...
Page 161: ...Maintenance 161 This page is blank...
Page 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Page 198: ...Specifications 198 2 HX S 030 400G4 F I...
Page 199: ...Specifications 199 3 HX S 060 100G4 F I...
Page 200: ...Specifications 200 4 HX S 060 200G4 F I...
Page 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Page 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Page 203: ...Specifications 203 7 HX S 01000 6G4 F I...