![Takara Belmont DIVAN-Z AB-DVZF Operation Manual Download Page 34](http://html1.mh-extra.com/html/takara-belmont/divan-z-ab-dvzf/divan-z-ab-dvzf_operation-manual_3363550034.webp)
Chair does not move.
The power switch turns off when
using the service outlet.
Fan does not operate.
The fan stops
If any of the problems described below occur, conduct the checks outlined before requesting repair.
If the chair does not work normally even after performing the recovery procedures, immediately stop using
the chair, turn off the power, unplug the power plug, and contact your authorized Takara Belmont dealer.
Problem
Check Points
Recovery Procedures
Is the power plug fully inserted to the
base of the plug?
Is the power switch turned on?
Has a fuse of the shop's switchboard or
breaker been tripped?
Has the chair been operated for an
extended period continuously?
Is the total amount of current used less
than the allowable value?
Has there been a short circuit in one of the
devices connected to the service outlet?
Isn't the backrest reclining more than
120°?
Isn't operation for more than 8 minutes?
Isn't the backrest reclined more than
120°?
Fully insert the power plug into the outlet until
reaching the base of the plug. (p. 14)
Turn on the power switch. (p. 14)
Replace the fuse of the switchboard or turn on
the breaker.
The problem is due to the operation of the
overheating prevention device.
⇒
Wait for about 10 minutes and try again.
This is a protective circuit that prevents
abnormal overheating of internal mechanisms
due to continuous operation and similar causes.
The chair might stop moving temporarily.
The breaker function operates if the current
used exceeds the allowable value.
Use an amount of current that is less than the
allowable value, and turn on the power again so
that the chair will operate normally.
This function prevents damage to this chair if
the chair is used when the allowable current is
exceeded.
Switch to using a different device and try
turning on the power switch.
Raise the backrest to be less than 120°, and
operate the fan switch again. (p. 29)
This is due to the operation of the automatic
stop function.
When the backrest is reclined more than 120°,
raise it to be less than 120°, and operate the fan
switch again. (p. 29)
Overheating Prevention Device
Breaker Function
These are not malfunctions
Sound at startup
Slow movement of the chair
Sound when rotating the chair
Such sound is due to the internal hydraulic fluid being cold. It is not a functional
fault and should stop shortly thereafter.
Such movement is due to the internal operating fluid being cold. Raise the room
temperature or continue operating for a short period. It will recover to the normal
condition.
This is the sound of the steel balls rolling when the chair is rotated. The level of this
sound varies depending on the environment where the chair is installed.