background image

8

Time Setting Key

Mist Level Lamp

Light

Heavy

1

2

3

4

Use this to change the time that has been set.
Pressing on

        (

 UP ) and       ( DOWN ) together will change 

the time in 1-minute increments each time they are pressed.
Keeping the keys depressed will change the time in 
succession (0 to 60 minutes).

Mist Level Key

Use this to change the amount of mist.
Pressing on it will increase the level by one 
each for time it is pressed.
(The level will revert to Level 1 after Level 4 
has been reached)

Control Panel

Level*

Mist Amount

Lamp Color

Yellow

Red

start /stop Key

Use this to start the operation of each mode.
Use this to stop operation.
Pressing the start key after a mode has been exited will 
result in starting under the settings that were in effect the 
time before. (Removing the power plug will invalidate the 
operating mode settings)

cooling Key

Select whether or not to use cooling after the Mist 
operation stops.
(Cooling is ON when the lamp is lit)

*

In operation at a low Mist Level setting (1, 2) no mist may be visible to the naked eye for a short 

 period after operation begins (about a minute); however, a misty breeze is actually being emitted.
 This is not a malfunction.

Summary of Contents for Ak-200

Page 1: ...sily referred to when necessary Contents Usage Safety Cautions and Warnings 2 Assembly Instructions 5 6 Location of Warning Labels Specifications 4 Component Parts 7 Control Panel 8 Positioning the Un...

Page 2: ...ernal section gets hot during operation and may cause burns if touched If a foreign body falls into the internal section turn off the power and contact our service center or sales office Keep hands an...

Page 3: ...oloration Do not move the main unit using the Nape Bar This may lead to the unit tipping over and may cause damage to the Nape Bar Do not apply force to the Hood This may lead to the unit tipping over...

Page 4: ...e Main Unit 3 After putting back the Water Container turn on the power If the indicator is no longer showing of OF you can start operation If the indication is still displayed after performing the mea...

Page 5: ...ix the Base Stand AY 200 in position with the bolt and tool 1 Attach the accompanying Support Cap in the direction shown in the illustration Main Unit Hood Side Depression Depression Cutout Support Ca...

Page 6: ...Be sure to remove the washer and sleeve Leaving them attached to the Support may cause damage to the product 4 Loosen the Height Adjustment Knob Be sure that the main unit can be moved up and down 3 A...

Page 7: ...Water Container Handle Water Container Holder Water Container Cap Drain Cock Main Unit Front Handle Power Switch Face Guard Nape Pad Height Adjustment Knob Nape Bar Main Unit Section Power Cord Drain...

Page 8: ...Control Panel Level Mist Amount Lamp Color Yellow Red start stop Key Use this to start the operation of each mode Use this to stop operation Pressing the start key after a mode has been exited will r...

Page 9: ...ding on usage The Standard Hood Internal Temperature is the temperature at approximately 5 minutes after the start of operation In operation over long periods of time the actual temperature may be sli...

Page 10: ...the Water Container Cap and add the water Caution Caution Always purify tap water before using it Use either water from the accompanying Takara Water Purifier TJ 5 or water that has been specifically...

Page 11: ...be eased by using the 2 tabs in the upper section of the frame and covering from top to bottom 3 Tighten the strap in the bottom section of the Face Guard Adjust the upper section strap the resin cor...

Page 12: ...ter part of the back of the turban Move the Main Unit to behind the customer Towel Turban Height Adjustment Knob Turban Rear Center Section 2 Open the upper cover and lower the Hood while checking the...

Page 13: ...en it is at Temperature Level 0 Thus the operations described above should not be attempted In these cases the display does not indicate a malfunction Turn off the power switch and then turn it on aga...

Page 14: ...e the machine is paused Changing conditions while paused Press the key that corresponds to the setting to be changed Operating Time Mist Level Temperature Level Cooling Enabled Disabled Change Operati...

Page 15: ...peration has ended the Unattended Time including the cleaning time will be displayed by flashing it on and off Fastener Removing the Face Guard 1 Open the Upper Cover 2 Press on the fastener button an...

Page 16: ...k water Remove the Drain Tank at the front of the Main Unit and discard the water accumulated in it 1 Raise the Hood 2 Move the Cock that keeps the Drain Tank in place to an upright position 3 Grasp t...

Page 17: ...ould be wiped clean periodically Hair stuck inside or chemicals may cause malfunctions and become a source of foul odors When treatment permanent or coloring chemicals come into contact with the unit...

Page 18: ...r in the Water Container Operation will resume after water has been added Indicates an excess of water 1 Turn off the Power Switch 2 Remove the Water Container and discard the water in the Main Unit 3...

Page 19: ...ake sure that the Power Switch has been turned on Make sure that the power plug is properly plugged into the outlet No mist comes out If the display is blinking p 18 p 18 If the display is blinking If...

Page 20: ...Memo 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Reviews:

Related manuals for Ak-200