- 8 -
WARNING
Do not install the heater where water, debris
or flammable vapors may get into the flue
terminal/opening. This may cause damage to
the heater and void the warranty.
Do not have the vent terminal/opening
pointing toward any opening into a building.
Do not locate your heater in a pit or location
where gas and water can accumulate.
Do not install this water heater under an
overhang less than 3 feet from its top or
eaves. The area under an overhang must be
open to three sides.
Do not install the water heater vent terminator
within 1 ft. in the USA of any air intake or
building opening, and with in 3 ft. in Canada
of any air intake or building opening (Refer to
p.13).
Avoid locating the water heater exhaust
opening near
any air intake devices
. These
fans can pick up the exhaust flue products
from the water heater and return them to the
building. This can create a health hazard.
Prohibited
Prohibited
Prohibited
T-K3-OS
T-K3-SP