Vane Damper
FYN-X2 Series
*Max. angle
*Operating temperature
*Weight
*Body material
*Cap material
*Rotor material
*Oil type
106
°
-S~SQ°C
287±10g
Zinc die-cast (ZDC)
Zinc die-cast (ZDC)
Zinc die-cast (ZDC)
Silicone oil
I
How to Use the Damper
I
Specifications
Model
Max. torque
FYN-X2-R154
lSN•m
--------------------------------
FYN-X2-L 154
(1 S0kgf·cm)
FYN-X2-R254
25N·m
--------------------------------
FYN-X2-L254
(250kgf ·cm)
Note) Measured at 23'C±2'C
--+-1-----i,,_____,-----\llf-----l-+-!
1.0perating characteristics of self-adjusting oscillating dampers
Reverse torque
2 N•m or lower
(20kgf·cm).)
... CF)
3 N•m or lower
(30 kgf•cm or lower)
Directions
Clockwise
------------------------------------------
Counterclockwise
Clockwise
------------------------------------------
Counterclockwise
(495)
46.7±0,5
(37.7)
- -
,
(30)
17.5
(2)
Hex hole
In a conventional oscillating damper. the damping strength (damping constant) does not change regardless of the load torque used.
Therefore. the operating speed is slower when the load torque is small, and faster when the load torque is large.
However, since the self-adjusting FYN-X2 series is designed to self-adjust the damping strength (damping constant) according to the
applied load, its motion-time fluctuates less than that of conventional dampers when the load changes.
The acceptable range of torque is 1 O to 1 SN•m or 20 to 25N•m. Please select your damper by referring to the motion-time graph below.
Rotor
Valve (flat spring)
Direction of torque generation
[Motion time graph]
20�-----, ----�
,
____ _
u
17.5 ---------------,
--
Conventlonaltype
� 15 ---------------:
---
Self-adjustingtype
� 12.5 --- ----------:--------------
'9 1 0 ------- ------i --------------
6
7.5 ------------ --�--------------
!
S
r���
,.._.
--
__:
:::;:
�
�
2.5
020
22.5
25
Load torque [N · ml
12.5
15
Load torque [N · ml
[Operating principles of the self-adjusting type]
As shown in the diagram to the left, by changing the shape of the valve (flat spring),
the amount of oil flow is altered, adjusting the damper's generated torque. (PAT.P)
[Measurement conditions for the motion-time graph]
��
g,o
·�
�b
QJ
"'
:,:;
00
C:
�
[
0
FYN-X2 25N•m specification
• Measuring temperature :
Room temperature(23±3
°
C)
• Load torque: 20~25N•m
• Measuring angle: +30
°
~-30
°
��
00
C:
-�
�b
QJ
"'
:,:;
00
C:
�
[
0
FYN-X2 1 SN•m specification
• Measuring temperature :
Room temperature (23±3
°
C)
• Load torque: 10~1 SN•m
• Measuring angle: +30
°
~-30
°
As the level of self-adjustment may vary depending on the range of the
working angle of the actual work, please verify under actual working
conditions before you select your damper.