5.10. CUTTING CHAIN BELT REPLACEMENT
Disconnect the machine from the drive or unplug the power cord from the electrical outlet.
Remove the drive protection (41-Figure: 22), remove the housing cover (42-Figure: 22), remove the drive
cover (43-Figure: 22).
Remove the lubrication pump (44-Figure: 22).
Loosen the belt tensioner (45-Figure: 22).
Remove the belt (46-Figure: 22) from the driven pulley (47-Figure: 22).
Remove the old belt and clean the area.
Install the new belt.
Position the belt onto the pulleys.
Tension the belt and reinstall removed elements: lubrication pump (44-Figure: 22), drive protection (41-
Figure: 22), housing cover (42-Figure: 22), drive cover (43-Figure: 22).
After one hour test operation, recheck the tension of the belt (disconnect the machine from the drive).
Perform additional tension controls every 50 hours of operation.