![Tait TB7100 Installation Manual Download Page 6](http://html2.mh-extra.com/html/tait/tb7100/tb7100_installation-manual_3294727006.webp)
6
Installation
TB7100 Installation Guide
© Tait Electronics Limited May 2005
1.4
Environmental Conditions
1.4.1
Operating Temperature Range
The operating temperature range of the TB7100 base station is –30°C to
+ 60°C (–22°F to + 140°F) ambient temperature. Ambient temperature is
defined as the temperature of the air at the intake to the cooling fans.
1.4.2
Humidity
The humidity should not exceed 95% relative humidity through the
specified operating temperature range.
1.4.3
Dust and Dirt
For uncontrolled environments, the level of airborne particulates must not
exceed 100 µg/m
3
.
1.5
Grounding and Lightning Protection
1.5.1
Electrical Ground
The TB7100 base station modules are grounded by physical contact
between the module mounting points and the chassis. To ensure a good
ground connection you must tighten each module securely (refer the
Installation and Operation Manual chapter
“Replacing Modules”
for the
correct torque).
A threaded grounding connector is provided on the rear of the tray for
connection to the site ground point (refer to the Installation and Operation
Manual chapter
“Connection”
for more details).
1.5.2
Lightning Ground
It is extremely important for the security of the site and its equipment that
you take adequate precautions against lightning strike. Because it is outside
the scope of this manual to provide comprehensive information on this
subject, we recommend that you conform to your country's standards
organisation or regulatory body.