Appendix A
T-336Cx S-register Table
-5-
bit
5
,
4
- data length on direct mode
00 - 8 bits (6-N-1)
01 - 9 bits (7-N-1)
*10 - 10 bits (8-N-1)
11 - 11 bits (8-Stuff Parity –1)
bit
7
,
6
- guard tones
*00 -
AT&G0
Disabled
01 -
AT&G1
550
Hz
10 -
AT&G2
1800
Hz
11 -
reserved
No Default Unit
Function
Description
S24
01000000 binary
Bit Mapped Options
bit
1
,
0
- DTR off-to-on control
*00 -
AT%D0 normal
(108.2)
01 - AT%D1 dial/ans according to ring-in (108.1)
10 -
reserved
11 -
reserved
bit
3
,
2 -
reserved
bit 7-4
- Login check
0000..1001 -
#0..#9
1010 -
ALL
1011 By
NMS
1100 Disable
S25 00
100ms DTR
Debounce
Time
bit
3
,
2
,
1
,
0
- DTR drop detection time
bit
7
,
6
,
5
,
4
- DTR rising detection time
S26
0
10ms
RTS to CTS Delay
S27
00001000 binary
Bit Mapped Options(set /clear)
bit1
,
0
- data mode data format
*000 -
AT&Q0
,
&M0
async data mode
001 -
AT&Q1
,
&M1
sync data mode
010 -
reserved
011 -
reserved
Summary of Contents for T-336C Series
Page 2: ......
Page 12: ......
Page 14: ...1 TAINET MODEM 2 V 13 V 23 4 2...
Page 21: ...2 1 2 2 1 Description MODEM TRS16 TRS32...
Page 24: ...2 4 2 4 Site Selection MODEM 10 15 6 1 83 MODEM TRS 16 NMC 16 TRS 32 NMC 32 TRS16 TRS32...
Page 25: ...2 5 2 5 AC Electrical Outlet Connection MODEM 90 265V AC 2A 4A DC Source Power Supply 36 72VDC...
Page 27: ...2 7 ON OFF DTE PHONE LEASED DIAL RJ11 RJ11 RJ11 RJ11 2 1 Dial Line...
Page 29: ...2 9 2 2 Leased Line...
Page 30: ......
Page 35: ...3 5 1 2 LL TX Level 10dBm R Protocol type Auto MNP V42 ENTER EXIT...
Page 56: ......
Page 57: ...4 1 4 4 1 PREVIEW...
Page 70: ...4 14 10 Retrains 1 STATUS MENU Remote Access REMOTE STATUS MENU ON B E R Test...
Page 72: ...4 16 4 14 Intelligent Dial Multiplexer Controller AT LCD 10 108 1 DTR Off ON...
Page 85: ...6 1 6 6 1 Description...
Page 86: ...6 2 6 2 Instruments...
Page 87: ...6 3 6 3 Periodic Manintenance A B...
Page 89: ...6 5 6 5 Return Procedure 02 2658 3000 10 6444 9830 1...
Page 90: ......
Page 102: ......
Page 105: ...Appendix C T 336Nx LCD Menu Quick Reference 65 Appendix C T 336Nx LCD Menu Quick Reference...