3.3 Power supply requirement
a.
Acceptable voltage fluctuation : normally
±
10%vlt.
b.
Acceptable frequency fluctuation :
±
1HZ (50/60HZ)
c.
Acceptable momentary power-off duration: less than10m.sec
d.
Acceptable voltage impulse
The Peak value : 200% or less than the line voltage of the actual value(rms. value)
Duration: 1.5m.sec or less
e.
Acceptable AC voltage of the waveform distortion.
f.
Acceptable imbalance of the line voltage: 5% or less
g.
Power capacity table
TPR-1230H & TPR-1230
Main Motor
2.25Kw
Elevating Motor
0.75Kw
Hydraulic Motor
0.75Kw
Coolant Pump Motor
0.1Kw
The total power requirement should be 9.753KVA
TPR-1600H
Main Motor
5.625Kw
Elevating Motor
1.5Kw
Hydraulic Motor
0.75Kw
Coolant Pump Motor
0.1Kw
The total power requirement should be 20.203KVA
TPR-2000H
Main Motor
5.625Kw
Elevating Motor
2.25Kw
Hydraulic Motor
0.75Kw
Coolant Pump Motor
0.1Kw
The total power requirement should be 22.193KVA