Taifun power source
Operation manual
Menu item
Letter
Value
Description
Voltage (U) in Volt (V), Current (I) in Ampere (A)
Voltage and current can be adjusted in steps of 0.1V and 0.1A.
"U6.0" means 6.0V; "I2.5" is 2.5A.
H
ot start
H 0
H
0, 1,
or 2
In hot-start the Taifun increases the output power to 150%, in order
to heat up the coil more quickly. Default setting: "0".
Hot-start 0 ("H 0")
The hot-start is turned off. No increased output power
Hot-start 1 ("H 1")
Hot-start level 1: Increased output power for 0.5sec.
Hot-start 2 ("H 2")
Hot-start level 8: Increased output power for 0.8sec.
Note:
The Overdrive is only possible within the absolute operation
limits! With a setting of, for example, (close to) 8.0V as the set point,
the hot-start does not affect the operation!
F
unction
F U
F
P, U,
or I
With this menu item you can decide which control mode you want to
use. When you change the function, the current set value is automat-
ically converted.
The Taifun supports power ("F P"), voltage ("F U") and current ("F I").
Default setting: "F U".
C
ut-off threshold
C32
C
2.8V –
3.5V
The cut-off threshold is the voltage at which the Taifun turns itself off
to
protect the battery
. Select a higher value, so the battery will last
longer. With a lower value, the operating time is extended until the
next battery change. Factory setting: 3.2V.
Note battery manufac-
turers cut-off voltage!
A
long, red flashing
will occur before device shuts off. The device
then remains switched off until the battery is changed.
A
larm threshold
A35
A
2.9V –
3.6V
When the battery voltage falls below this value, the Taifun "warns"
you that a
battery change is pending soon
. It signals this by
switching the
button illumination
to
red
during operation. Default
setting: 3.5V.
L
ight
L 2
L
0, 1,
or 2
Use this menu item to control whether and how the button is illumin-
ated when pressed. Factory setting: "2".
Button illumination 0 ("L 0")
The button is not illuminated during operation, unless the Taifun is
operated at its upper limits (see also section "Messages").
Button illumination 1 ("L 1")
The button is only illuminated in red when the battery voltage falls
below the alarm threshold.
Button illumination 2 ("L 2")
The button is always illuminated. Green during normal operation, red
for below the alarm threshold.
© 2013 SmokerStore GmbH
Page
: 9 of 16