7 Register Map
16
FY400/600/700/800/900 COMMUNICATION MANUAL
Register Address
Parameters
HEX
DECIMAL
MODBUS
Function Code
Setting Range
TM_62
Run Time of Seg.6
(Pattern 2)
0031 049 03/06/10H
OUT62
Output Limit of Seg.6
(Pattern 2)
0032 050 03/06/10H
SV_72
Set Point of Seg.7
(Pattern 2)
0033 051 03/06/10H
TM_72
Run Time of Seg.7
(Pattern 2)
0034 052 03/06/10H
OUT72
Output Limit of Seg.7
(Pattern 2)
0035 053 03/06/10H
SV_82
Set Point of Seg.8
(Pattern 2)
0036 054 03/06/10H
TM_82
Run Time of Seg.8
(Pattern 2)
0037 055 03/06/10H
OUT82
Output Limit of Seg.8
(Pattern 2)
0038 056 03/06/10H
P1
OUT1 Proportional Band
0039 057 03/06/10H
0~2000
I1
OUT1 Integral Time
003A 058 03/06/10H
0~3600
D1
OUT1 Derivative Time
003B 059 03/06/10H
0~900
DB1
Dead-band Time
003C 060 03/06/10H
0~1000
ATVL
Auto Tuning Offset
003D 061 03/06/10H
CYT1
OUT1 Cycle Time
003E 062 03/06/10H
0~150