7. Wiring note:
Select the appropriate wiring method according to the range of voltages measured to
ensure that the input voltage is within the tolerance of the instrument.
Note: The input voltage range of its own power supply: 6V~80V;
External power supply input voltage range: 0V~120V.
8. Feature introduction and settings
(1)
“
NCP
”
charging overcurrent protection value. If the value is greater than 0, the
protection will be activated. If it is equal to 0, the protection function will not be
activated. When setting the parameters, click the up or down button to move the
cursor to
“
NCP
”
, then click the OK button. Enter the parameter setting interface of
Figure (8-1). After entering the page, it will prompt the nature and range of the set
parameters, then click the up or down button to change the size of the set parameter
value. Note: The current display line will be set when the parameter is set. Change to
red and display the wireless return value of the set parameter. When the set
parameter value and the current display line data match, the data setting is
completed (ignoring the decimal point), then click OK to return to the initial interface
to complete the parameter. Settings and save.
PIC.(8-1)
(2) "OCP" discharge overcurrent protection value. If the value is greater than 0, the
protection will be started. If it is equal to 0, the protection function will not be
activated. When setting the parameters, click the up or down button to move the
cursor to
“
OCP
”
, then click the OK button to enter the parameter setting interface of
the figure (8-2). The parameters are set in the same way as
“
NCP
”
.