![Taidacent VAC8010F Manual Download Page 12](http://html1.mh-extra.com/html/taidacent/vac8010f/vac8010f_manual_3232607012.webp)
www.banggood.com
12
PIC.(8-6)
(8)
“
BPC
”
battery remaining capacity setting, you can estimate the remaining battery
capacity according to the actual use situation. With this option, you can set the
remaining capacity of the battery, which is more convenient for testing. When setting
the remaining capacity of the battery, the parameter setting is completed when the
real-time percentage and the set percentage are the same, as shown in Figure 8-7.
PIC.(8-7)
(9)
“
CER
”
current return function. If the actual current value is zero and the
instrument display value is not zero, move the cursor to this option and press OK to
zero the current.
(10)
“
RET
”
data reset function, if you want to return to zero watt hour and run
accumulated time value, move the cursor to this option, short press OK to reset
these two parameters to zero.
(11) "LNG" language switching function, the instrument parameters are preset with
Chinese and English interfaces to choose from, enter the parameter setting page as
shown in Figure 8-8, click the up or down button to switch the language type.