This
product is an indoor combustion gas detector with high
stability , hereinafter called detector, used for combustion gas
leak detection. It uses highly stable semiconductor gas sensor
with features of stable performance and low drift of
sensitivity. When it senses combustion gas leak that reaches
the set alarm level, it will give out alarm sound with red LED
flashing. The detector is applied in indoor places where
combustion gas leaks possibly happen.
PRODUCT INTRODUCTION
PRODUCT PROFILE
Solenoid
Valve
(optional accessory)
manual
pole
control
line
(connect
with
detector)
Wire harness connection instruction for DC type detectors :
Red: DC power anode
Black: DC power cathode
White: COM (relay)
Yellow: N.C. (relay)
Orange: N
.
O
.
(relay)
Wire harness connection instruction for detectors for AC type detectors
(no wire harness attached for stand alone type detectors):
Red: anode of solenoid valve
Black: cathode of solenoid valve
White: COM (relay)
Yellow: N
.
C
.
(relay)
Orange: N
.
O
.
(relay)
FEATURES
Wall
Manual
Test/Auto
Reset
Functions
High Capacity Relay (3A/250V)
●
●
Mounted
●
Highly
Stable
Semiconductor
Gas
Sensor
●
Adopts MCU Processing
●
●
Auto
Check
Malfunction
●
●
SMT
Manufacture
Technology, High Stability
●
Comply
to
GB15322
.
2
-
2003
Detects Natural Gas/LPG
TECHNICAL
SPECIFICATION
1
Voltage
DC9
-
24V AC220V
Highly Stable Semiconductor Gas Sensor
Working Envir.
Type
-10ºC ~ +55ºC, 10%~95%RH (no congelation)
Storage Temp.
Power: Green
LED ON
Dimension
-25ºC ~ +55ºC
DC12V 300ms
Reset
Relay or Solenoid Valve
Signal Output
Auto
Reset (Leaked
Gas
Level< Alarm Level)
Sensor
Alarm: Red LED Flashing
Fault: Yellow LED ON
Relay
1C(SPDT),
Contact
loads:
3 A 250 VAC/30 VDC
Alarm
Level
6%LEL
110*70*40mm
Error
±
3
LEL
%
DC Type
AC Type
Solenoid
Valve
Signal
Sound
Level
75dB/1m
Indicator
Output
Relay Output
INSTALLATION
1
.
First
identify
your
gas
heavier
or
lighter
than air
.
Heavier
gases: LPG etc. Lighter gases: natural gas, marsh
gas, artificial coal gas etc.
2.
Choose a suitable installing position according to gas
specific gravity. Detecting heavier gases, installation
height 0.3-1.0m from floor , semi-diameter to gas source
<1.5m; Detecting lighter gases, installation height 0.3-
1.0m from ceiling, semi-diameter to gas source < 1.5m
(refer to the following image).
C E I L I N G
F L O O R
DETECTOR
GAS STOVE
Max
Range
:
Φ3m
Combustion
Gas
Detector
Manual
3. Fix the attached base into a wall firmly with screws
and hang the detector.
4. Do not make it close to gas stoves when installing at home
in case it is roasted by flame. Neither places with heavy oil
or smoke that may cause false alarms or block the gas
convection holes and influence the detector sensitivity.
Also it is can not be installed near to exhaust fans,
windows, doors, and places with great vapor in bathrooms.
5. Connect the wires correctly according to the wire harness