XT-1 Installation Manual
13-111 02, 2014-RO-012, 2014-04-30
Page 30 of 32
9 Technical Specification
Operating frequencies
XT-1 eu: 865.6-867.6 MHz Europe,
XT-1 us: 902-928 MHz US, Americas
Read range
Up to 8 meters (26ft) with TagMaster UHF tags with
SecureMarkID®; Windshield ID-tag and ISO-Card ID-tag
Dimensions
300x300x60 mm (11.8x11.8x2.4 in)
Weight
2.3 kg (5.1 lbs)
Ingress protection
IP 66
Operating temperature
-40°C to +60°C (-40°F to +140° F)
EN 60068-2-1 Ad, En 60068-2-2 Bd, EN 60068-2-14 Nb
Storage temperature
-40°C to +85°C (-40°F to +185°F)
Housing
Aluminium housing UL94 certified XENOY™ cover
Power supply
12-24 VDC supply
Power consumption
10W (max 12W)
Output power
XT-1 eu 2W (e.r.p.), XT-1 us 4W (e.i.r.p.)
Input
3 isolated inputs
Output
3 isolated outputs shared with Wiegand/Magstripe
Relay
1 relay output 60VDC, 2A
Interfaces
RS232, RS485, Wiegand/Magstripe, 2 pcs Ethernet and
USB service Interface
Certificates
CE Certificate according to R&TTE-directive 1999/5/EC and FCC
RoHS Directive 2002/95/EC and 2011/65/EU
WEEE 2002/96/EC
Standards
EPC Gen 2 (ISO 18000-6C)
LED indicator
Red/Green/Yellow
Communications protocols
TAGP and various OEM protocols
Encrypted air interface
According to EPC Gen 2 (ISO 18000-6C)
EMC
EN 301489-1, EN 301489-3
Radio
EN 302 208-1, EN 302 208-2
FCC: CFR 47, Part 15 subpart C, FCC ID: M39XTXX
Safety & health
EN 60950-1, EN 60950-22 & 1999/519/EC
Mechanical
EN 60068-2-27 Ea, EN 60068-2-64 Fh
Manuals and documentation
XT-1 Installation Manual, 13-111
TAGP Manual, 05-172
Part No.
XT-1 eu: 152500, XT-1 us: 152600
Accessories
Universal Mounting Kit: 193600
ISOcard ID-tag: 225000
WindShield ID-tag: 221000