Operations Manual
SV-4103-X4
Part Number: 1007610
Page 40 of 80
Version 1.1. 09/29/2009
Input Current: 20.0A (RMS) for 24VDC.
Inrush Current: 20.0A Max.
Temperature range: operating 10
℃
~
40
℃.
Humidity:operating:20%-95%, non-
operating:10%-95%.
Remarks: 85% is normal condition and 95% is
with special coating process.
Hold up time1.6ms minimum at full load &
nominal input voltage.
Dielectric withstand: input/output 1500 vac for
1 second.
Input to frame ground 1500 vac for 1 second.
Efficiency: 65% typical at full load*power good
signal: on delay 100ms to 500ms.
Overload Protection
:
130±20%.
Over Voltage Protection:
+5v→5.5v
~
7.0v ,
+3.3v→4.0v
~
4.5v.
Short Circuit Protection: +5v
、
+12v
、
+3.3v.
Emi Noise Filter :fcc class a, cispr22 class a.
Safety : ul 60950, csa 22.2 iec60950, tuv
en60950.
Remote on/off Control.
The unit shall accept a logic open collector
level which will disable/enable all the output
voltage (e5v stand by).
As logic level is low, outputs voltage were
enable.
As logic level is high, outputs voltage were
disable.
Cooling :two 40mm dc fans.