F3 series 100X5R service manual
29
11.0 technical data
11.1 100X5R Technical Specifications
Specification
Load
Conditions
units
Output power
8O
continuous
>100
W
4O
short term
>150
W
2O
short term
>190
W
Channel Balance
<0.2
dB
Sensitivity
8O
1W
.103 ± 0.02
V
Gain
1kHz
28.8 ± 0.2
dB
Input impedance
>20
KO
Signal/Noise
ref 0dBW 20Hz - 20kHz BW
>90
dB
ref 0dBW ‘A’ wtd.
>93
dB
Frequency response
20Hz - 20kHz
0 -0.15
dB
-3dB
0.2 & 75k
Hz
-1dB
0.4 & 48k
Hz
Overload headroom
8O
IHF 1kHz 8O
>2.2
dB
4O
IHF 1kHz
>2.5
dB
2O
IHF 1kHz
>3.0
dB
THD+N
8O
100W 20Hz - 20kHz 80kHz/500kHz BW
<0.02/<0.05
%
4O
150W 20Hz - 20kHz 80kHz BW
<0.03
%
Crosstalk
@ 1kHz
< -80
dB
abbreviations
E=Europe/Asia, N=North America, UK=United Kingdom
general
The rated and typical performance applies when the mains supply voltage is either 230V AC
for 220 - 240 V units or 115 V AC for 110 - 120 V units.
We reserve the right to alter design and specification without notice.
Specification may vary for different countries.
Summary of Contents for 100 5R Series
Page 1: ...amplifier 100x5R service manual ...
Page 10: ...F3 series 100X5R service manual 6 ...
Page 25: ...F3 series 100X5R service manual 21 Sheet 2 of 3 283 MICROCONTROLLER PCB SCH28206 02 03 ...
Page 26: ...F3 series 100X5R service manual 22 Sheet 3 of 3 283 MICROCONTROLLER PCB SCH28206 03 03 ...
Page 27: ...F3 series 100X5R service manual 23 ...
Page 29: ...F3 series 100X5R service manual 25 Sheet 2 of 2 283 AMPLIFIER SCHEMATIC SCH28301 02 04 ...
Page 30: ...F3 series 100X5R service manual 26 9 5 100X5R TAG BUS PCB ...