F3 series 100X5R service manual
15
6.0 performance tests
6.1 Test equipment required
Equipment
Specification
Signal Generator
20 Hz to 20 kHZ 100mV - 2V rms
Distortion Analyser
20 Hz - 20 kHz
Distortion measurement 0.001% or better
Voltage measurement 0.003 V to 10 V
dB scale -90 dB to +10 dB
Digital Multimeter
Accuracy better than 0.5% in V and mV ranges
Oscilloscope
Bandwidth >100 MHZ
load
8
O
x2
Various Leads
Signal Generator to RCA phono x2, 4mm to analyser & to load, 1KO
phono terminator
6.2 Performance test procedure
For test point
(TP)
references, see section 6.0 test points.
No
Action
Test
Details
Equipment
6.2.1
Switch off AC
power button
6.2.2
Connect
Audio signal
Switch on and allow to unmute.
amplifier as
generator
Measure signal output level:
shown in Figure
1kHz, 100mV
2.83Vrms
5.1
6.2.3
Measure
Distortion
With equipment set up in bandpass
channel
analyser
mode @ 20kHz, connect input
separation
output: 20 kHz,
signal to one AUDIO INPUT and
1 V rms
the other INPUT TERMINATED
measurement
WITH 1kO, with signal OUTPUT to
mode:
distortion analyser. Both outputs
Bandpass
should be terminated with 8O.
amplitude
.
Measure signal level. Set as 0 dB
reference. Move analyser input
over to other channel. Signal level
should reduce by more than 85 dB,
typically 90 dB.
Summary of Contents for 100 5R Series
Page 1: ...amplifier 100x5R service manual ...
Page 10: ...F3 series 100X5R service manual 6 ...
Page 25: ...F3 series 100X5R service manual 21 Sheet 2 of 3 283 MICROCONTROLLER PCB SCH28206 02 03 ...
Page 26: ...F3 series 100X5R service manual 22 Sheet 3 of 3 283 MICROCONTROLLER PCB SCH28206 03 03 ...
Page 27: ...F3 series 100X5R service manual 23 ...
Page 29: ...F3 series 100X5R service manual 25 Sheet 2 of 2 283 AMPLIFIER SCHEMATIC SCH28301 02 04 ...
Page 30: ...F3 series 100X5R service manual 26 9 5 100X5R TAG BUS PCB ...