8.  Technical specification   

 

Type of emission:

  

 

ISM Band – 869 MHz 

Code :

 

 

 

 

4 differentiated Channels (A, B, C, D)  

Radiated Power Output :

   100 

mW 

Range:

 

 

 

 

1 km under optimal conditions, direct view 

Timing Impulse Inputs:

 

 

 

Open Working contact. Respect the polarities (Black = Ground) 

Precision:

 

 

 

 

Fixed delay of 200ms +/- better than 0.13 millisecond. 

Signal Transmission Evidence:

  By audible tone (buzzer) and LED (1, 2, 3, 4) 

 

Signal Reception Evidence: 

By audible tone (buzzer) and LED (1, 2, 3, 4) 

Signal Reception Monitoring: 

By 4  LED’s. Control of the quality of the reception and of eventual 
disturbances. 

Power Supply: 

  Transmitter: 

 

Battery 3V (CR123A – 1400mAh) 

 

  Receiver 

:

  

LiPol battery– 2200mAh  

 

  

 

 

charger HL540-1 (12V / 1.25A)

  

Autonomy : 

  Transmitter: 

365 days / Stand-by  

 

  

 

 

45 days / impulses every 10 sec ( 388'000 impulses) 

 

  

Receiver : 

 

48h / impulses every 10 sec (17’280 impulses) 

Operating Temperature Range:

   -20°C à + 60 °C 

 

 

 

Dimensions & weight 

Transmitter 

  

: 147 x 57 x 32 mm / weight of 225 gr. 

 Receiver

         

: 185 x 82 x 32 mm / weight of 425 gr. 

 
 
 

Guaranty:

 

Two years starting from the purchase date  

 

 

The guaranty is null and void under the following conditions:

 

Accumulators or battery out of use 

  

-  

Bad maintenance and obvious damages

 

-  

Input or Outputs damaged by bad connection 

 

 
 
 

Summary of Contents for HL 615

Page 1: ...TAGHeuer Timing Page 1 8 IMPULSE RADIO TRANSMISSION SYSTEM HL 615 Operating Instruction Version 03 2015 ...

Page 2: ...sly or not from 4 Transmitters identified by the function CHANNEL 1 to 4 with a precision of 0 13 ms The delay of transmission is 200 ms and the distance in good condition up to 1000 m 2 Presentation 2 1 Transmitter 1 Input Impulse Banana plug 2 Function SET 3 Function Channel chapter 4 Function Team chapter 5 Function Test and ON Set Test 6 Function BATT and OFF Set Batt 2 2 Receiver 1 Output Imp...

Page 3: ... switch OFF the receiver press together button SET and POWER 3 2 INPUT Transmitter Input for timing impulses start gate photocells working closing contact Respect the polarities 3 3 OUTPUTS Receiver Output of the timing impulses isolated by opto coupler 1 to 4 working closing contact Respect the polarities 3 4 SET To program the TEAM A B C D or CHANNEL 1 2 3 4 and to switch OFF the receiver Mainta...

Page 4: ...er works with a LiPol battery of 3 7V 2200mAh Use our 12V power supply HL540 1 with 500mA minimum The LED Power show the charge state Receiver OFF Charge active Slow flashing LED Charge Finished Led OFF Receiver ON Charge active Fast flashing LED Charge Finished Led ON The full charge could take up to 4 hours The autonomy is up to 48h with impulses every 10 secs 6900 impulses The receiver is autom...

Page 5: ...change battery 1 Remove the two screws with a torx screwdriver n 9 2 Remove gently the bottom cover 3 Remove the circuit where the battery is fixed 4 Exchange the battery CR123A and replace the circuit to the Transmitter Warning that the 6 connexion pins are well placed 5 Screw back the cover without forcing Standard autonomy Transmitter OFF 365 days Transmitter ON 45 days impulses every 10 sec Tr...

Page 6: ...f a photocell is out of alignment WARNING For proper operation it is essential that the transmitters and the receiver are not closer than 2 meters WARNING It is forbidden to operate transmitter without antennas it may damage the electronic radio transmitter 7 Installation recommendation For good transmission it is recommended that antenna are placed 1m above ground Transmitter Receiver should be p...

Page 7: ...ng By 4 LED s Control of the quality of the reception and of eventual disturbances Power Supply Transmitter Battery 3V CR123A 1400mAh Receiver LiPol battery 2200mAh charger HL540 1 12V 1 25A Autonomy Transmitter 365 days Stand by 45 days impulses every 10 sec 388 000 impulses Receiver 48h impulses every 10 sec 17 280 impulses Operating Temperature Range 20 C à 60 C Dimensions weight Transmitter 14...

Page 8: ...euer Timing Page 8 8 TAG Heuer PROFESSIONAL TIMING 6A Louis Joseph Chevrolet 2300 la Chaux de Fonds Switzerland Tel 032 919 8000 Fax 032 919 9026 E mail info tagheuer timing com Http www tagheuer timing com ...

Reviews: