TAG
Heuer Timing
Page 19 / 49
8. JUMPING MODE (details)
These three modes allow you to time in Stand-Alone a Jumping Race (with or without Jump-Off) directly with our
Chronoprinter 540.
With these modes, you will be able to add and remove Penalties, Stop/Restart, automatically calculate points
penalties, time limit penalties (phase 1 or 2) and also automatically add Pause Penalties wh/they are required.
8.1. Input
Configuration
Input 1: Start Jumping Timing
Input 2: Jump-off (only for modes “Jumping 2 Phase or Jumping Sng Phase”)
Input 3: Start Count down, Pause & Restart
Input 4: Finish
8.2. (Menu: Jumping Parameters)
-
Set Count Down
Set the count down before the start signal (30 or 45 sec).If countdown is not required you set to 0. If setting
to 0 each competitor has to be validated by pressing input 3 prior manually.
-
Set Race Time Ph1
Set the Time limit for Phase 1 (sec)
If the value is set at “0”, no time penalties will be added.
-
Set Time P/Ph1
Set Penalty in Ph1 wh/time limit is exceeded (0.25 pts / sec)
-
Set Race Time Ph2
Set the Time limit for Phase 2 (sec)
If the value is set at “0”, no time penalties will be added.
-
Set Time P/Ph2
Set Penalty in Ph2 wh/time limit is exceeded It is possible to set the points penalties / time (example: “0.25
pts / 1 sec” or “1.00 pts / 4 sec”)
-
Set Pause Penalty
Set a default Time Penalty if pause is requested (sec)
8.3. Timing Mode: Jumping Speed
Wh/you have configured the race (Jumping Parameter) and also configured the other important parameters
including Input Numbering (auto/Manual) and lock time (see CP540 user manual), you are ready to op/a new
run.
The normal sequence for this Timing Mode is
-
Start Count Down (Input 3) : will start the session for a new competitor
-
Start Race (Input 1)
-
Finish Race (Input 4).
During a jumping race, the competitor will pass through the photocells several times. All these passings will be
recorded and printed to the CP 540.
To validate a time, you have 5 seconds after receiving the passing time to press Enter (
◄┘
)
All times recorded are available with the function Recall for post editing.
Each competitor will be defined into the Chronoprinter as a group of times betwe/the Start Count Down (Input
3), ev/if the Count Down value is setting at “0”.(from the first Input 3 – Start Count Down, to the last Input 4 –
Finish)