THE-100 Series
Rev 1
2020/11/27
15/18
Copyright © 2020 by TAEHA CORP. All Rights Reserved
5.4
Dispensing rate adjustment
5.5
Interval function(Intermittent dispensing)
No
Description
1
Adjustment
Decrease
Increase
Needle
thickness ↓
thickness ↑
Pressure
low
High
Dispensing
time
time ↓
time ↑
1) Adjust to Steady mode (continuous dispensing).
2) Gradually increase to the desired discharge rate at
the appropriate (desired) flow rate.
3) You can also adjust the discharge pressure to set
the desired flow rate and discharge amount.
⚠ Caution
- At first, adjust the discharge amount to a needle of
appropriate thickness by gradually boosting the
pressure from low pressure.
- Please note that there is a risk of material
scattering if the Needle is thick and high pressure.
2
Factors that can change the discharge rate
Dispensing time
Small amount
Needle change
Middle amount
Pressure
Large amount
1) Operate in Steady mode until the desired
discharge amount is shot s/w or foot s/w.
2) At this time, after memorizing the number in shot
time, select time mode and set the time with the
augmentation key.
3) With the time mode selected, proceed with the
discharge test and check if the discharge amount
is the one you want.
No
Image
Description
1
* Intermittent dispensing : A function that
repeatedly turns the machine ON and OFF while
the shot signal is ON
1) Press the Time and Steady keys on the front of the
controller for 3 seconds, and the shot time display
will blink.
2) Use after setting the off time of the increase /
decrease key.
3) After setting to low pressure, operate slowly in
steady mode until air comes off.