4
Operation
4.1
Precautions on use and assembly
4.1.1
In connection Stator(A) and Rotor(B)
Use C(Fix Tool) to fix the tools and apply solution(material) inside A(Stator) and on B(Rotor).
Connect A(Stator) and B(Rotor) and rotate them up to the marked position and rotate C(Fix Tool) in
clockwise direction.
Do not activate the pump without applying the material to the stator. If so, even for a short duration
of time, there might be a damage on the stator.
4.1.2
Eliminating bubbles before liquid dispensing
When the pump and the controller’s settings are finished, before applying the
solution to the product, rotate the D(Vent Knob) as the arrow direction one to
two rounds to discharge the bubbles and some liquid(about 5~10 seconds).
When it is confirmed that the bubbles are all eliminated, then close it off again.
When eliminate bubbles, set the motor speed at low(5~10RPM) to dispense.