Defective line fuse

a) Defective tachometer or interrupted

tachometer feedback, R91 missing

b) Interrupted armature feedback. Check jumpers

I

 and 

VII

, R82 missing.

c) Maximum speed potentiometer P9 intermittent.
d) Minimum speed potentiometer P6 intermittent.
e) Interrupted potentiometer connection from

terminal 5 to start of speed-potentiometer.

f) Wrong po/- on d.c. tachometer

connection. (Check terminal connection 11-20)

Drive runs at maximum speed, however

speed potentiometer is set for zero speed or

low speed

This concludes the preliminary preparation and adjustment of the

Thyristor-Drive-Control Type TA-15/6P...200/6P

a) Too low adjustment of current limit.
b) Motor is overloaded, mechanical defect on

machine or motor. Check motor brushess

c) Supply v/- 15V for electronic circuit

incorrect or missing. Reference v 10V

incorrect or missing. Check LED 5 and LED 2

d) Triggering of one Thyristor temporarely

interrupted. Defective tachometer or

tachometer leads. Defective minimum speed

potentiometer.

e) Defective speed potentiometer

a) Armature connections shorted or grounded.

Check power Thyristors.

b) Defective motor or armature. Check brushes.

a) Defective power supply
b) Jumper on the terminals 13-18 is missing
c) Check relay and relay supply
d) Defective speed potentiometer
e) Defective armature fuse
f) Check motor and motor brushes
g) Defective fuses Si 1, Si 2 or Si 3

Speed varies without change of the setting

of the speed potentiometer

Symptom

Drive does not run

Possible causes

Summary of Contents for TA-15/6P

Page 1: ...ntriebstechnik de TA_BA TA 15 200_6P_EN PDF The German text applies in cases of doubt TA 15 6P 200 6P Instruction and Operation Manual Caution There is always a risk involved in the handling of electr...

Page 2: ...al 4 and 9 Jog Speed ON Closing contact Drive remains switched on until contacts open 1 Technical Data r Motor Zero Speed Indicator r Current Limit control r Tachometer Signal control r Electronic cir...

Page 3: ...or speed r When tachometer feedback is utilized jumpers I and VII and resistor R82 must be removed r Jumpers IX and X must be installed and jumper VIII must be removed r The adaption of the tachometer...

Page 4: ...installed or when the reference speed is changed Current limit P5 Adjustment of the requested max armature current adjust the nominal motor current Minimum Speed P6 Adjustment of min speed during ope...

Page 5: ...center position Potentiometer P3 IxR Compensation set fully counter clockwise Potentiometer P8 Stability set in center position Potentiometer P7 Jog speed set fully counter clockwise Potentiometer P1...

Page 6: ...iometer P8 This potentiometer must be adjusted so that the drive operates without overshoot in the presset speeds 5 2 Tachometer feedback control 1 Check all connections with an Ohm meter for grounds...

Page 7: ...tive fuse Si 1 on the upper PC board c LED 8 Power on does not light up d LED 9 does not light up however LED 11 lights up jumper or quick stop contacts terminals 24 and 25 not closed e No reference v...

Page 8: ...Type TA 15 6P 200 6P a Too low adjustment of current limit b Motor is overloaded mechanical defect on machine or motor Check motor brushess c Supply voltage 15V for electronic circuit incorrect or mi...

Page 9: ...VITESSE D ACCROCHAGE Reglerfreigabe ALTERNATIF FIELD DC TACHOMETER Sollwertpotentiometer Schleichgang JOG SPEED DEBLOCAGE RUN EXCITATION Feld Anker Netz INDUIT ARMATURE ALIMENTATION EN LINE FAULT DOC...

Page 10: ...changes reserved Instruction Operating Manual TA 15 6P 200 6P 8 Mounting template TA 40 6P TA 60 6P 200 6P TA 15 6P 310 270 165 7 x 13 270 350 KL1 310 270 165 7 x 13 400 270 460 40 KL3 KL1 KL2 530 486...

Reviews: