Tador Technologies
CD-500
Installation guide
3
Changing the programming code
Enter the programming code: if not changed is: 123456 confirm with *, the green led will
blink.
now the following sequence should be entered: memory cell number 99 , new programming
code ,and for verification again the memory cell number 99, the same new programming
code. Confirm with *.
Now you can add access codes in cells 01-98 as described or exit.
To finish press:
֠
֠
֠
֠
.
For example changing the programming code to: 649731.
Press: 123456
*
,
99
then
649731
and again
99
and
649731
confirm with
*
.
To finish press:
֠
֠
֠
֠
.
You should keep this code because this is the only way to enter the programming
mode!
Back to Initiate status – default
Using an internal jumper the initial programming code can be restored. The access codes will
not be changed.
Turn the power off. dismount the panel. Install a jumper on pins labeled:
DEFAULT
turn on
the power, a long “Beep” will be sound for confirmation.
Turn off the power and take out the jumper. Reinstall the panel.
The Intercom Encoder returns to normal condition. The Programming code now is: 123456 *.
Canceling an access code
A particular access code could be cancel if its memory cell location is known.
Enter the programming code: if not changed is: 123456 *, the green led will blink.
now the following sequence should be entered: memory cell number to cancel(2 digits), and
֠
֠
֠
֠
֠
֠
֠
֠
.for verification again the same memory cell number, and
֠
֠
֠
֠
֠
֠
֠
֠
. Confirm with *.
For example: canceling the code stored in cell number 37:
press the following sequence:
⇒
123456
*
,
37
֠
֠
֠
֠
֠
֠
֠
֠
37
,
֠
֠
֠
֠
֠
֠
֠
֠
*.
To finish press:
֠
֠
֠
֠
.
Setting opening times values
A different opening time value can be set to opening via the keyboard and via the optional
bypass pushbutton.
The times values are from 1 second till 9 seconds.
Enter the programming code: if not changed is: 123456 *, the green led will blink.
now the following sequence should be entered: memory cell number 00, opening time via
keyboard (1 digit) followed by opening time via bypass pushbutton (1 digit). for verification
repeat the same sequence of memory cell number 00 opening times values. Confirm with *.
To finish press:
֠
֠
֠
֠
.
Remark: when setting the keyboard opening time, a value to the bypass pushbutton must be
set also, even if not installed.
For example setting the keyboard opening time to 5 sec. And pushbutton to 7 sec.
Press: 123456
*
,
00
then
5 then 7
and again
00
and
5 and 7
confirm with
*
. To finish
press:
֠
֠
֠
֠
.
Summery and examples
Programming option
execution
default
Entering programming code
⇒
123456
*
Changing programming code
For example: new code 777456
Enter programming code,
*
⇒
99-777456 99-777456
*
֠
֠
֠
֠
123456
Storing a new access code
For example: cell number 01
access code: 2040
Enter programming code,
*
⇒
01-2040 01-2040
*
֠
֠
֠
֠
All the cells are empty
(not 0)
Canceling access code stored in
cell number 37
Enter programming code,
*
⇒
37-
֠
֠
֠
֠
֠
֠
֠
֠
37-
֠
֠
֠
֠
֠
֠
֠
֠
*
֠
֠
֠
֠
Setting opening time from
keyboard to 2 seconds and from
bypass pushbutton to 5 seconds
Enter programming code,
*
⇒
00-25 00-25
*
֠
֠
֠
֠
3 seconds from
keyboard,
3 seconds from bypass
pushbutton