General: 

The 5 wires encoder unit is an intercom system, serves as door 
panel and encoder. 
With this unit you can speak with the visitor who is waiting at  
the door and open the electric lock from the intercom handset or 
from the phone using Tador 5 wires adapter. 
Authorized personnel can open the door by pressing  
An access code.   
By programming appropriately, each user can get an  
individual access code. 
The device includes an environment resistant and anti  
vandal metal keyboard. 
An optional bypass pushbutton enables easy internal  
opening (the opening time is programmable)

 

 
Features: 

Easy installation, programming and 
operating. 

Power failure resistance, keeps the access 
codes in nonvolatile memory 

up to 98 simultaneously different access 
codes 

Environmental and anti vandal resistance. 

Different and programmable opening time 
from keyboard and bypass pushbutton  

Up to 1 million possible combination codes  

optional bypass exit pushbutton 

 

 
Specifications: 

Operating voltage: AC 12V 800mA   

Code length: 2-6 keys 

Operating electric or magnetic lock. (normally 
open or normally close)   

Opening time: 1-9 seconds 

Color: silver or bronze 

Size:  under plaster195X115X50mm (H*W*D) 
On the wall 154X100X35mm (H*W*D) 

 
Installation: 

J5 should be set accordingly to the door lock type (3 pins jumper) 

Desirable RLY state when entering valid code 

Jumper J5 

Close circuit  (Normally open) for electric lock 

Jumper on 2 left pins (default state) 

Open circuit  (Normally close) for magnetic lock 

Jumper on 2 right pins  

After installing the lock in the door frame. Route the following wires to the Intercom Encoder: 

1.

 

2 wires from power supply. 

2.

 

2 wires from the lock. 

3.

 

5 wires from Intercom handset. 

4.

 

2 wires from optional bypass pushbutton. 

Using a Phillips screwdriver open the top cover, carefully pull up the panel. 
Using a screw driver, expose the 4 covered insulations bores and the round wirings bore. 
Attach the base of the Intercom Encoder to the wall, using a pencil mark the 4 fixing points. 
Drill the 4 fixing points on the wall. 
Route the wires through the round bore in the base of the Intercom Encoder. 
Using 4 screws install the base to the wall. 
Verify the power supply is not connected to power source! 
Connect the wires to the circuit board terminal blocks according to the circuit’s labels, the 
attached electrical diagram and the following instructions. 
Connect: Power supply to the two 

12VAC 

terminals. 

One wire from the lock to the 

RLY

 terminal. The second wire from the lock to one of the 

12VAC

 terminal.  Short wire from the second 

12VAC

 terminal to the second 

RLY

 terminal. 

 (The 

RLY

 functions as a switch) 

Surface 

Mount

  

Flush/Surface 

Mount 

Summary of Contents for CD-500

Page 1: ...35mm H W D Installation J5 should be set accordingly to the door lock type 3 pins jumper Desirable RLY state when entering valid code Jumper J5 Close circuit Normally open for electric lock Jumper on 2 left pins default state Open circuit Normally close for magnetic lock Jumper on 2 right pins After installing the lock in the door frame Route the following wires to the Intercom Encoder 1 2 wires f...

Page 2: ...ing code and 4 digits for access code Programming code access codes and opening times values are programmable via the keyboard Programming mode in order to store new access code set opening times or changing the programming code you should enter to the Programming mode After clicking the valid programming code manufacturer code if not changed is 123456 confirm with the green led is blinking now yo...

Page 3: ...the same memory cell number and Confirm with For example canceling the code stored in cell number 37 press the following sequence 123456 37 37 To finish press Setting opening times values A different opening time value can be set to opening via the keyboard and via the optional bypass pushbutton The times values are from 1 second till 9 seconds Enter the programming code if not changed is 123456 t...

Page 4: ... or low gently rotate the internal MIC potentiometer clockwise to lower volume Operation Calling at the door Press shortly on the Bell Wait for vocal answer If authorized the lock will buzz and you may enter Opening the lock using the keyboard Enter the access code confirm with The lock will be open for the time value it was programmed Each key stroke is followed by a Beep sound entering a false c...

Page 5: ...C connected for electric lock Power Supply 12V AC 12 VAC To avoid noises COM and power supply must be connected separately and directly to this point PRG Normally open electric lock Normally close magnetic lock Comelit handset Amplyvox handset Videx Smart 1P handset T R 1 0 Z 1 2 3 5 6 4 P1 3 2 The second buzzer connection 3 7 5 6 1 2 Videx handset COM Lock Buzzer SP MIC Line coming in Routing ADS...

Reviews: