Tadiran Domestic Pool Type Technical Manual TCAC-RTSM-20150203
21
Hydraulic circuit test pressure: 0.3 MPa. Hydraulic circuit operating pressure: 0.15MPa.
Average water flow 5.5m
3
/h-pressure drop 0.022MPa.
Water pump selection
Model
Water flow
Recommend flow
LRSJ-60/NYN1
0.8~20m
3
/h
3m
3
/h
LRSJ-80/NYN1
0.8~20m
3
/h
4m
3
/h
LRSJ-120/NYN1
1.5~20m
3
/h
5m
3
/h
LRSJ-140/NYN1
1.5~20m
3
/h
5.8m
3
/h
Water treatment
In order to use our appliances under the best conditions, the following parameters must be
respected:
Maximum
concentration of free chlorine is 2.5 mg/L.
Maximum concentration of total bromine maximum is 5.5mg/L.
PH value is between 6.9 and 8.0.
If chemical or electrolyte disinfection systems are introduced, the installer and user must
contact the supplier to ensure they are compatible with our materials. These systems must
be installed after the heating system.
Item
Requirements
Free chlorine
≤
2.5 mg/L
Total bromine
≤
5.5 mg/L
PH value
6.9
<
PH
<
8