LTA-2 WIRING CROSS REFERENCE

Power Connections

Output Contacts

Manufacturer

Device or Series

Hot

Neutral

Common

To Burner

To Water

Feeder /

Alarm

Taco

LN/LTA-2 Series

H

N

COM

NC

NO

McDonnell & Miller

PS-801/851 (Older Models

w/Red & Amber LEDs)

1

2

3

5

4

McDonnell & Miller

PS-801/851 (New Models

w/Red & Green LEDs)

H

N

C

B

W

McDonnell & Miller

PS-802/852 (Older Models

w/Red & Amber LEDs)

H

N

C

B

W

McDonnell & Miller

PS-802/852 (New Models

w/Red & Green LEDs)

H

N

C

B

W

McDonnell & Miller

Series 750

1

2

3

4

5

McDonnell & Miller

RB - 122

H

(Black Wire)

N

(White Wire

)

C

(Yellow Wire)

B

(Yellow Wire)

-

McDonnell & Miller

RB - 120

1

2

3

4

5

McDonnell & Miller

RB - 24

Red Wire

White Wire Yellow Wire Yellow Wire

-

Hydrolevel

24

Black Wire White Wire

-

Orange

Wire

Brown

Wire

Hydrolevel

170

H

GN

P1

P2

A

Hydrolevel

400, 500, 600, 700, 450,

550, 650, 750

1

2

P1

P2

A

Honeywell

RW700 Series (Except

RW700A1098)

L1

L2

-

B

A

Honeywell

RW700A1098

T1

T2

-

B

A

 

LWCO Ordering

 

!&$"%$!

#$%$$! 

A -

%$!$#$

Reset Type

024

 

120 -

 

Input Power

Process Connection

3

(

S -

$ ""!$"!

(! '

Probe Styles

Probe Only Ordering

  

Probe

S -

$ ""!$"!

(! '

Probe Styles

Process Connection

3 -

(

Summary of Contents for LTA-2

Page 1: ...ing NEMA 1 for indoor use only Input Power 2 8 VA 120 VAC 2 8 VA 24 VAC supplied by a Class 2 power source Reset Automatic reset when water level returns to safe level Testing Integrated test switch for testing safety shutdown US Patents 6 904 800 7 243 540 and 7 317 993 Other Patents Pending Installation must be performed by qualified personnel and in accordance with all national and local codes ...

Page 2: ...robe so that the exposed portion of the stainless steel is a minimum of 1 4 from any grounding surface inside the boiler to prevent the probe from shorting See Fig 2 4 Tighten probe securely with a wrench using bushing flats provided Use pipe thread sealant to seal the probe threads tures Status LED Service LED Test Button Do not tighten by grasping the device enclosure Use wrenching flats on the ...

Page 3: ... the two mounting screws in the probe bushing are loosened approximately 1 8 from the bushing surface 3 Then remove the first lock washer nut from the probe threads 4 Orient the slotted holes in the control unit over the heads of the mounting screws of the probe and turn control unit counter clockwisesothattheendsoftheslotsarefullyunderthemounting screw heads Tighten mounting screws 5 Replace the ...

Page 4: ...onnect wire from the hot side of the water feeder or alarm to terminal NO Be sure the power source for Control Unit and burner circuit are the same voltage Make sure you are not introducing a second voltage source into the burner circuit via the jumper This will bypass other operating limit and or safety controls which may result in property damage personal injury or death Testing 1 DO NOT fill bo...

Page 5: ...dels w Red Green LEDs H N C B W McDonnell Miller Series 750 1 2 3 4 5 McDonnell Miller RB 122 H Black Wire N White Wire C Yellow Wire B Yellow Wire McDonnell Miller RB 120 1 2 3 4 5 McDonnell Miller RB 24 Red Wire White Wire Yellow Wire Yellow Wire Hydrolevel 24 Black Wire White Wire Orange Wire Brown Wire Hydrolevel 170 H GN P1 P2 A Hydrolevel 400 500 600 700 450 550 650 750 1 2 P1 P2 A Honeywell...

Page 6: ...NTAL COSTS OF REMOVING OR REPLACING DEFECTIVE PRODUCTS This warranty gives the purchaser specific rights and the purchaser may have other rights which vary from state to state Some states do not allow limitations on how long an implied warranty lasts or on the exclusion of incidental or consequential damages so these limitations or exclusions may not apply to you Symptom Possible Cause Remedy Boil...