2
Installing the Hot-LinkPlus-e Hot-Link Valve:
1. Select the hot water faucet furthest from the water heater. If
your plumbing system branches in two different directions,
another
Hot-Link Valve
may need to be installed at the end of
each run
(see Figure 1 on page 1)
.
3. Open the hot and cold faucets to purge water from the lines.
4. Disconnect the hot and cold flex hoses from the 1/2" faucet
connections beneath the sink and reconnect them to the
respective hot and cold inlet ports on the
Hot-Link Valve
.
Locate the flow arrows on the side of the valve to verify flow
direction.
5. Install the 1/2" x 1/2" flex hoses provided. Connect one hose
to
the hot outlet of the valve and the hot water connection on
the
faucet (left side). Connect the second flex
hose to the cold
outlet of the valve and the cold water connection on the faucet
(right side).
See Figure
5
below.
6. When all connections are made, open angle stop valves and
check for leaks.
7. Attach the
Hot-Link Valve
to the wall using anchor
screws provided.
N
OTE
:
The Hot-Link Valve can be disassembled for service and
cleaning. Repeat steps number 2 and 3. Unthread the valve stem
from the body and clean internal screen of debris
(see Figures 3 &
4 above)
. Reattach valve stem securely to prevent leaks. Open
angle stop valves and check for leaks.
Hot
Shut-Off
Valve
Shut-Off
Valve
1/2” Male
(2) New 1/2”x1/2”
Taco® supplied flex lines
(female x female)
Use (2) existing female
x female flex lines
1/2” Male
Hot-Link®
includes (2)
plastic wall anchors
& screws
Cold
1/2”
3/8” Male
3/8” Male
1/2”
HOT
COLD
CAUTION: Do not use pipe dope or Teflon tape on the
valve body threads.
CAUTION: Use caution when attaching flex hoses to the Hot-Link
Valve to prevent cross-threading or stripping of the threads.
Hot-Link Valve
Hot-Link Valve removable cartridge for service
Application:
T
aco's Hot-LinkPlus-e
SmartPlug Instant Hot Water Control is
designed to upgrade any hot water recirculation system.
SmartPlug replaces inefficient timers and aquastats typically used
in recirculation systems. It adds intelligence to your system by
learning when hot water is used in the home. The pipe-mounted
sensor records daily hot water usage patterns during the course
of the week. Recorded data is used to automatically run the
006e3
at the same times the following week. So hot water is
awlays available when it is needed. If usage pattern changes, the
SmartPlug adjusts automatically.
Installing the Hot-LinkPlus-e SmartPlug Instant
Hot Water Control®:
Benefits:
Easy to Install:
Upgrades
the Hot-LinkPlus-e 006e3
circulator
to
“Smart” operation.
Comfort and Convenience:
Hot water is available in seconds. No
timers or programming required.
Efficiency:
“Smart” mode maximizes hot water comfort and energy
savings.
Reliabili
t
y
:
The
SmartPlug, when combined with
the 006e3
circulator, provides whisper quiet operation and industry leading
electronics for proven performance and dependability.
2. Shut off the hot and cold angle stop valves below the sink.
Figure 5:
Diagram is for reference only
Figure 3:
Figure 4:
SmartPlug Control Options/Features:
“Smart” Mode:
When set to Smart mode, the SmartPlug will run
in Pulse mode as described below for the first 7 days of
operation. During the first 7 days, the SmartPlug monitors and
records the home's hot water usage pattern. For the following
7 days, the SmartPlug will use the preceding week's usage
pattern to cycle the
006e3
during the recorded hot water
usage times. This process of recording and repeating is
continuous, and automatically adjusts the
006e3
ON times to
match the household's usage pattern.
“Pulse” Mode:
When set to Pulse mode, the SmartPlug will cycle
the
006e3
ON for 5 minutes, then OFF for 10 minutes to
maintain hot water at all faucets and taps. It will repeat the
cycle continuously.
Vacation Mode:
After 36 hours of no hot water usage, the
SmartPlug will automatically turn the
006e3
OFF, and will
automatically restart when hot water usage is detected.
Exercise Function:
While in vacation mode, the SmartPlug will
cycle the
006e3
ON for 10 seconds every 7 days to
prevent corrosion or scale buildup
.