background image

Model #:     554-8 Wireless Remote Transmitter Button

Includes:        1 Remote Transmitter Button

6. Place the control board back into the remote receiver cover and reinstall the cover by

aligning the four plastic posts on the base with the four holes in the cover. Make sure

the white wire is properly inserted into the cover cutout. Gently snap the cover and

base together.

PROGRAMMING INSTRUCTIONS

1. Unplug the TacoGenie circulator from the 115V wall outlet.

2. Remove the remote receiver cover (rectangular black box wired to the TacoGenie cir-

culator) separating the top cover from the base plate. A small straight tip screw driver

may be used if necessary. Lift the control board out from the case.

NOTE:

The  remote  transmitter  button  is  provided  with  a  “coin”  type  lithium  battery

installed  in  the  remote  transmitter  and  is  ready  for  programming.  554-8  Remote

Transmitters purchased separately must be synced with the remote receiver.

3. Plug the TacoGenie circulator back into the 115V wall outlet. Circulator will automati-

cally turn on and operate until hot water is detected at the TacoGenie temperature

sensor.

4. A  red  LED  will  light  on  the  remote  receiver  electronic  control  board  once  the

TacoGenie is plugged into the wall outlet. The remote receiver must be powered with

the red LED on to properly sync remote receivers.

5. Next to the red LED is a small black button. Press and hold down the black button

and a yellow LED on the other side of the black button will light. While the yellow LED

is on, press and hold the 554-8 Remote Transmitter Button for 3 seconds. Release

the transmitter button, then release the remote receiver button and the yellow LED

will turn off. The Remote Transmitter Button is now synced and ready for operation.

Control Board

Base

Cover

Black Button

Yellow LED

Red LED