background image

-6-

5.  Wiring the circulator: 

Disconnect the AC power supply. Remove 

the terminal box cover. Attach a wiring connector into the knockout 

hole. Use a flexible conduit only.  Connect Line/Hot power to the black 

lead, neutral to the white lead. See wiring diagram to the right. Replace 

the terminal box cover.

Note:

 If pigtail leads provided are not used, be sure to trim field wire to a 

strip length of .25” (+/- .025”) to prevent exposed wire causing a short at the 

terminal plug. Connect line and neutral to green terminal plug as shown 

in the Wiring Diagram. Depress the spring tab with a small screwdriver to 

insert wire into the plug. Release tabs to complete connection. The 007e is  

a double insulated circulator. No grounding wire is necessary.

6.  Start the circulator: 

When purging the system, it is recommended 

to run the circulator long enough to remove all remaining air from 

the bearing chamber. This is especially important when installing the  

circulator in the off-season. An orange LED will illuminate when the 

0015e3 is powered on.

7.  Green Mode: 

Responsive technology actively monitors system conditions and automatically adjusts to optimize power 

consumption. In this mode the LED changes to green. Consult with the factory for directions to access Green Mode.

CAUTION: 

Never run the circulator dry or permanent damage may result.

ATTENTION: 

Ne laissez jamais le circulateur tourner à sec, des dommages  permanents peuvent en résulter.

WARNING:

 Use supply wires suitable for 90°C.    

 

 

 

 

 

 

 

AVERTISSEMENT: 

Employer des fils d’alimentation adeqauts pour 90°C.

WARNING:

 Disconnect power when servicing.

AVERTISSEMENT:

 Couper l’alimentation lors de l’entretien.

CAUTION:

 Use flexible conduit only. Not for use with rigid conduit. 

AVERTISSEMENT:

 N’utiliser que du conduit flexible ; n’est pas fait pour du conduit rigide.

WARNING: 

SERVICING OF DOUBLE-INSULATED APPLIANCES. A double-insulated appliance is  

 

marked with one or more of the following:
The words “DOUBLE INSULATION” or “DOUBLE INSULATED” or the double insulation symbol (square within a 

square). In a double-insulated appliance, two systems of insulation are provided instead of grounding.  

 

No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added. 
Servicing a double-insulated appliance requires extreme care and knowledge of the system, and should be  

done by qualified service personnel. Replacement parts for a double-insulated appliance must be identical  

to the parts they replace.

Full Speed Operation:

To run the pump at full speed during the fast fill, start-up and purge process, rotate dial to HIGH setting.    

 

To return to the normal operating mode, turn dial to desired LOW, MEDIUM or HIGH setting.

Summary of Contents for 0015e3

Page 1: ...tions Use on open loop potable hot water recirculation systems with up to 1000 feet of pipe or closed loop hydronic heating systems Not suitable for chilled water systems Taco circulator pumps are for indoor use only employer uniquement a l interieur Acceptable for use with water or maximum of 50 water glycol solution FEATURES Three easy settings to match system requirements LOW MEDIUM HIGH Replac...

Page 2: ...ricant pour connaître la compatibilité de liquides CAUTION Installations at elevations over 5000 feet must have higher fill pressure of 20 psi minimum to prevent pump cavitation and flashing Premature failure may result Adjust expansion tank pressure to equal fill pressure A larger size expansion tank may be required ATTENTION Des installations à des altitudes de plus de 1600 mètres doivent présen...

Page 3: ...n system Open all isolation valves Once system is filled close the fixture at the highest point in the system Close isolation valve on pump discharge Option No 1 location Open drain valve on pump discharge until all remaining air has been purged Close drain valve Operate pump until all remaining air is purged from bearing chamber 2 3 4 5 6 7 ...

Page 4: ...Open FF valve Open V2 PV4 to purge last zone First Zone 3 Close FF Valve Close V2 PV4 Repeat steps 1 to 6 for each additional zone purge zone 1 last Open V1 when all zones are purged Adjust system to desired operating fill pressure if required 2 3 4 5 6 7 8 9 V1 V2 V3 Shut off Isolation Valve P Taco circulator with IFC installed FF Fast Fill Boiler Feed Valve PV4 Purge Valve ...

Page 5: ...ing the circulator See page 3 for recommended air purging steps CAUTION To reduce the possibility of noise transmission be sure to add vibration dampeners to piping when mounting circulator to wall or floor joists ATTENTION Pour réduire la possibilité de transmission de bruit veillez à ajouter des amortisseurs de vibration à la tuyauterie lors du montage du circulateur sur des chevêtres de mur ou ...

Page 6: ...to access Green Mode CAUTION Never run the circulator dry or permanent damage may result ATTENTION Ne laissez jamais le circulateur tourner à sec des dommages permanents peuvent en résulter WARNING Use supply wires suitable for 90 C AVERTISSEMENT Employer des fils d alimentation adeqauts pour 90 C WARNING Disconnect power when servicing AVERTISSEMENT Couper l alimentation lors de l entretien CAUTI...

Page 7: ...ressure variable speed HIGH 18 feet of head max full fixed speed CAUTION Do not attempt to remove LED panel from circulator Serious damage to circulator electronics may result ATTENTION N essayez pas de retirer le panneau de LED du circulateur Des dommages sérieux à l électronique du circulateur peuvent en résulter Selection options are LOW MEDIUM or HIGH On HIGH setting the 0015e3 runs at full sp...

Page 8: ...or impeller rotation 7 If the circulator still doesn t run it will need to be replaced FAULTS CONTROL PANEL CAUSES REMEDIES The circulator is noisy LED on Suction pressure is insufficient cavitation Increase the system suction pressure within the permissible range LED on Presence of foreign bodies in the impeller Disassemble the motor and clean the impeller Loud noises of water circulation Flashin...

Page 9: ...ilpiece set UFS 075P 3 4 Press tailpiece set Lead FreeShut Off FLANGE SOLDSEPARATELY Part Description SFL 050T 1 2 NPT SFL 050S 1 2 Sweat SFL 075T 3 4 NPT SFL 075S 3 4 Sweat SFL 100T 1 NPT SFL 100S 1 Sweat SFL 125T 1 1 4 NPT SFL 125S 1 1 4 Sweat SFL 150T 1 1 2 NPT SFL 150S 1 1 2 Sweat 9 Taco Grundfos Armstrong Xylem B G Wilo 005 006 007 008 0015 007e UP15 10 UP15 42 UPS15 55 UPS15 58 Alpha 15 55 A...

Page 10: ... 10 NOTES ...

Page 11: ... 11 NOTES ...

Page 12: ...consequential damages so these limitations or exclusions may not apply to you LIMITED WARRANTY STATEMENT Taco Inc will repair or replace without charge at the company s option any Taco product which is proven defective under normal use within three 3 years from the date code In order to obtain service under this warranty it is the responsibility of the purchaser to promptly notify the local Taco s...

Reviews: