background image

GRAND SLAM 1000  / 7 

The power button on the control panel for the GS-

1000 is a lock-down button. When pressed, the button 

will light up and stay on until pressed again. Each time 

the power button is pressed, the system will reset 

the electronic system to the default setting. If the 

system is shut off with outriggers in outward position, 

outriggers will stay in position until proper buttons are 

pushed to return outriggers to the default position.

Operation Manual for Outriggers Control Panel

POWER BUTTON (A)

The Port Mount/Starboard Mount (STBD) are lock-

down buttons (left/right) for which side outriggers 

you are wanting to work with. Choose desired side 

and press down button (will lock in). When button is 

in center position, lift or rotate button will not work. 

PORT MOUNT / STARBOARD MOUNT (STBD) (C)

When wanting to lift up/down outriggers, choose 

the side (Port or STBD Mount) and lock down. And 

then click the lift button (Up/Down) until you have 

reached the desired level. With each click, the lights 

will light (up or down) on the side you are working 

on (Port/STBD Mount). When you reach the desired 

level position, stop clicking the up/down button and 

the outrigger will stay at that level until changed by 

operator.

LIFT UP / DOWN BUTTON (E)

When wanting to rotate outrigger (Out/In), choose 

the side (Port or STBD Mount) and then press and 

hold down the unlock button (B) and press rotate 

in/out button.  By holding this button down, the 

outrigger will move outward/inward, depending on 

which arrow you are pushing. Arrows are switched 

when using either Port Mount or Starboard Mount 

(STBD). Follow the arrow directions when choosing 

sides. For example, the left arrow will rotate the Port 

outrigger away from boat with Port selected and will 

bring STBD outrigger in when STBD is selected. When 

reaching the desired location position, let off button 

to stop motion. Outrigger will stay in this position until 

changed by operator.

ROTATE (OUT/IN) BUTTON (D)

Keeping the Lower switch (E) depressed for more than five (5) seconds will return the outrigger 

to the 0° position.

              *NOTE:     

In case of mechanical pump failure, there is a rocker switch mounted on the pump 

assembly, and depressing this switch will manually lower the outriggers to where 

they can be removed.

Summary of Contents for GRAND SLAM 1000

Page 1: ...GRAND SLAM 1000 ELECTRO HYDRAULIC OUTRIGGER MOUNT INSTALLATION OPERATION INSTRUCTIONS TACO Marine Grand Slam Outrigger Mounts...

Page 2: ...T JIG SAW SILICONE SEALER 8 5 16 18 STAINLESS STEEL BOLTS LENGTH BASED ON APPLICATION 7 16 1 2 9 16 OPEN END WRENCHES MIGHTY VAC BLEEDER OPTIONAL Required not included 1 GS 1000 starboard head 1 Pump...

Page 3: ...a pie plate access cover The other option is a threaded backing plate made into the hardtop The control box and manifold must be mounted in a dry area within 2 feet of each other Installation Requirem...

Page 4: ...ews It is most efficient to mount the pump to the left of the manifold Mount the manifold either to the right or below the pump assembly Note Port configuration P in the recommended layout 3 Route thr...

Page 5: ...ntrol box the connectors are color coded Green Green and Black Black 3 Attach the main power cables to a 40 amp fuse or circuit breaker red wire to the Positive 12V and Black for the Negative Electric...

Page 6: ...osition to allow operation of the Rotation Switch D This prevents unintentional rotation of the outrigger arm 3 C Port Starboard Select Switch This switch selects Lift E and Rotation D access to the s...

Page 7: ...wn on the side you are working on Port STBD Mount When you reach the desired level position stop clicking the up down button and the outrigger will stay at that level until changed by operator LIFT UP...

Page 8: ...8 GRAND SLAM 1000 Use a Light Hydraulic oil ISO 32 like Mobile DTE 24 of an automotive ATF Fluid Approximate capacity 1 qt Hydraulic Ports Connection Diagram APPENDIX...

Page 9: ...GRAND SLAM 1000 9 Keypad Interface...

Page 10: ...Bleach Clorox etc and mild abrasive cleaners Ajax Comet Soft Scrub Rubbing Compounds etc Strong cleaners 409 Engine Degreasers etc Acids of any type Such as Muriatic naval jelly or aluminum acid Alwa...

Page 11: ...GRAND SLAM 1000 11 Need Support 1 800 653 8568 support tacomarine com tacomarine com 50 NE 179th ST Miami FL 33162 tacomarine taco_marine TACO Marine Contact Us We re here to help...

Page 12: ...12 GRAND SLAM 1000 LEFT BLANK INTENTIONALLY...

Page 13: ...00 percent for accurate sizing Slight scaling may still occur Therefore before drilling it is recommended that all template dimensions be measured for accuracy BOW STERN 6 00 GRAND SLAM 1000 13 GS 100...

Page 14: ...INSTRUCT GS 1000...

Reviews: