LIMITED WARRANTY STATEMENT

Taco, Inc. will repair or replace without charge (at the company’s option) any 

commercial pump product or part which is proven defective under normal 

use within one (1) year from the date of start-up or one (1) year and six (6) 

months form date of shipment (whichever occurs first).
In order to obtain service under this warranty, it is the responsibility of the 

purchaser to promptly notify the local Taco stocking distributor or Taco in 

writing and promptly deliver the subject product or part, delivery prepaid, to 

the stocking distributor. For assistance on warranty returns, the purchaser 

may either contact the local Taco stocking distributor or Taco. If the subject 

product or part contains no defect as covered in this warranty, the purchaser 

will be billed for parts and labor charges in effect at time of factory exam-

ination and repair.
Any Taco product or part not installed or operated in conformity with Taco 

instructions or which has been subject to misuse, misapplication, the addi-

tion of petroleum based fluids or certain chemical additives to the systems,

or other abuse, will not be covered by this warranty.
If in doubt as to whether a particular substance is suitable for use with a 

Taco product or part, or for any application restrictions, consult the

applicable Taco instruction sheets or contact Taco at [401-942-8000].
Taco reserves the right to provide replacement products and parts which 

are substantially similar in design and functionally equivalent to the defec-

tive product or part. Taco reserves the right to make changes in details of 

design, construction, or arrangement of materials of its products without 

notification.

TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS 

WARRANTIES. ANY WARRANTY IMPLIED BY LAW INCLUDING WAR-

RANTIES OF MERCHANTABILITY OR FITNESS IS IN EFFECT ONLY 

FOR THE DURATION OF THE EXPRESS WARRANTY SET FORTH IN 

THE FIRST PARAGRAPH ABOVE.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRAN-

TIES, EXPRESS OR STATUTORY, OR ANY OTHER WARRANTY OBLI-

GATION ON THE PART OF TACO.
TACO WILL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDI-

RECT OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE 

OF ITS PRODUCTS OR ANY INCIDENTAL COSTS OF REMOVING OR 

REPLACING DEFECTIVE PRODUCTS.

This warranty gives the purchaser specific rights, and the purchaser may 

have other rights which vary from state to state. Some states do not allow 

limitations on how long an implied warranty lasts or on the exclusion of in-

cidental or consequential damages, so these limitations or exclusions may 

not apply to you.

MAINTENANCE

A regular inspection schedule should be adopted and carried out

by competent personnel to examine the pressure vessel for corrosion 

and its cause, extent and possible arrest, to determine minimum metal 

thicknesses, maximum metal temperatures, calculation of reduction in al-

lowable working pressure and to conduct hydrostatic tests. Also, defects 

such as cracks, laminations and distortion of shell, heads or connections 

should be noted and repaired if possible, after consultation with and ac-

ceptance by a commissioned authorized inspector who shall be involved 

at all stages of any repairs or alterations of the ASME vessel.
In addition, the operation of the air vent, flush cock and drain valves, 

and switchable on/off magnet (if installed) should be checked for proper 

operation.

CAUTION: MAINTENANCE SHOULD ONLY BE UNDERTAKEN BY 

PROPERLY TRAINED AND QUALIFIED PERSONNEL. NEVER OPEN 

A VESSEL UNTIL THE SYSTEM PRESSURE IS OFF AND THE VES-

SEL HAS BEEN ISOLATED AND DRAINED. FAILURE TO FOLLOW 

THESE INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR 

DEATH.

The Taco automatic air vent located in the top of the air separator is 

designed to prevent system fluid or debris from fouling the venting mech-

anism. Periodically the flushing cock on the side of the separator should 

be opened by qualified personnel in order to clean any system debris 

which may have accumulated at the air/system fluid interface beneath 

the vent.

 CAUTION: MAINTENANCE SHOULD ONLY BE UNDERTAK-

EN BY PROPERLY TRAINED AND QUALIFIED PERSONNEL. CARE 

SHOULD BE UNDERTAKEN WHEN OPENING THE FLUSHING COCK 

AS SYSTEM FLUIDS MAY BE UNDER HIGH TEMPERATURE AND 

OR PRESSURE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY 

RESULT IN SERIOUS INJURY OR DEATH. 

This procedure should only 

be performed by properly trained personnel. 

Systems where Air/Dirt or Dirt separators are installed should be period-

ically blow down by properly trained personnel to remove sand, dirt or 

other system debris. The frequency of this cleaning is dependent upon 

the nature of the system fluid. Initially the system is blowdown after 

the first 12 hours of operation. Dependent upon the amount of debris 

removed during the blowdowns process, subsequent blowdown should 

be scheduled for a minimum of three minutes.
The blowdown process should be undertaken by trained personnel 

only.

 CAUTION: MAINTENANCE SHOULD ONLY BE UNDERTAKEN 

BY PROPERLY TRAINED AND QUALIFIED PERSONNEL. CARE 

SHOULD BE UNDERTAKEN DURING SYSTEM BLOWDOWN AS 

SYSTEM FLUIDS MAY BE UNDER HIGH TEMPERATURE AND PRES-

SURE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT 

IN SERIOUS INJURY OR DEATH.

Systems where Air/Dirt with the switchable on/off magnet or Dirt Sepa-

rators with the switchable on/off magnet are installed should follow the 

same process for Air/Dirt or Dirt Separators except should consider pro-

hibiting system flow followed by turning the magnet handle from the On 

to the Off position prior to performing the blow down to ensure magnetite 

is released from the internal magnet sleeve. 

CAUTION: MAINTENANCE 

SHOULD ONLY BE UNDERTAKEN BY PROPERLY TRAINED AND 

QUALIFIED PERSONNEL. NEVER OPEN A VESSEL UNTIL THE SYS-

TEM PRESSURE IS OFF AND THE VESSEL HAS BEEN ISOLATED 

AND DRAINED.

 4900s with Switchable on/off magnet option contain 1 or 

more high power magnet. 

If loss of system fluid is a concern, the separator should be isolated from 

the system by closing the adjacent valves as needed. Residual pressure 

within the separator should be reduced by slowly opening the factory 

installed blowdown valve. Make-up water may be introduced through 

the flushing cock located on the side of the separator to promote further 

rinsing of the internals of the separator without wasting system fluids.

THIS MAGNET SHOULD NOT BE REMOVED FROM 

THE VESSEL WITHOUT CONSULTING THE FACTORY.

 

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY 

RESULT IN SERIOUS INJURY OR DEATH.