background image

102-517A

SUPERSEDES: 

January 14, 2021

EFFECTIVE: 

August 16

, 2021

Plant ID No. 001-5000

007e

®

-2 

ECM High-Efficiency Circulator

DESCRIPTION:

The 007e-2 is a variable speed, high-efficiency wet rotor circulator with an ECM, permanent mag-

net motor. Its ECM performance is equivalent to the legendary Taco 007 and ideal for hydronic

systems zoned with circulators or zone valves. It reduces power consumption by up to 85% com-

pared to equivalent AC permanent split capacitor circulators.
APPLICATION:

• Maximum operating pressure: 125 psi (8.6 bar)
• Maximum water temperature: 230°F (110ºC)
• Electrical specifications:

Voltage: 110-120V, 50/60 Hz, single phase

             Maximum operating power: 44W

             Maximum amp rating: 0.54

• Equipped with a cast iron casing and should be used for closed loop systems only
• Not suitable for open loop potable water or chilled water systems
• Taco circulator pumps are for indoor use only – employer uniquement a l’interieur
• Acceptable for use with water or maximum of 50% water/glycol solution
• Not recommended for systems designed for constant circulation

FEATURES:

• ECM performance equivalent to the legendary Taco 007 circulator

• Multi-color LED display showing power on and error code diagnostics

• Use with a Taco Zone Valve Control (ZVC) or Switching Relay (SR) for ON/OFF operation

• Nut capture feature on flanges for easier fit up

• Dual electrical knockouts and 6” stranded wire leads for easy wiring

• Double insulated - no ground-wire required

• Whisper quiet operation

• BIO Barrier

®

protects the pump from system contaminants

• SureStart

®

- automatic unblocking and air purging mode

• Optional 2-way universal flange model for easy fit-up to any flange orientation

• Integral Flow Check (IFC

®

) included - Field installed

• Green Mode active system monitoring and power optimization

WARNING: Do not use in swimming pool or spa areas. Pump has not been investigated for these applications.

AVERTISSEMENT: Ne pas utiliser dans une piscine ou un spa. La pompe n'a pas été étudiée pour ces applications.

CAUTION: The addition of petroleum based fluids or certain chemical additives to systems using TACO equipment voids the war-

ranty. Consult factory for fluid compatibility.

ATTENTION: L'ajout de liquides à base de pétrole ou de certains additifs chimiques à des systèmes utilisant un équipement TACO

annule la garantie. Consultez le fabricant pour connaître la compatibilité de liquides.

CAUTION: Installations at elevations over 5000 feet must have higher fill pressure of 20 psi minimum to prevent pump cavitation

and flashing. Premature failure may result. Adjust expansion tank pressure to equal fill pressure. A larger size expansion tank may

be required.

ATTENTION: Des installations à des altitudes de plus de 1600 mètres doivent présenter une pression de remplissage plus élevée

de 20 psi au minimum afin d'éviter toute cavitation ou flashing de la pompe. Une défaillance prématurée peut en résulter. Réglez

la pression du réservoir d'expansion de façon qu'elle soit égale à la pression de remplissage. Un réservoir d'expansion d'une taille

supérieure peut être nécessaire.

Instruction Sheet

®

Standard flange model: 007e-2F2

Optional 2-way flange model: 007e-2F4

Figure 1:

-1-

Summary of Contents for 007e-2

Page 1: ... protects the pump from system contaminants SureStart automatic unblocking and air purging mode Optional 2 way universal flange model for easy fit up to any flange orientation Integral Flow Check IFC included Field installed Green Mode active system monitoring and power optimization WARNING Do not use in swimming pool or spa areas Pump has not been investigated for these applications AVERTISSEMENT...

Page 2: ...Figure 2 2 ...

Page 3: ...NG STEPS 1 CLOSE V1 PV4 V2 2 OPEN V3 AND ZV3 3 OPEN FF VALVE 4 OPEN V2 PV4 TO PURGE LAST ZONE FIRST ZONE 3 5 CLOSE FF VALVE 6 CLOSE V2 PV4 7 REPEAT STEPS 1 TO 6 FOR EACH ADDITIONAL ZONE PURGE ZONE 1 LAST 8 OPEN V1 WHEN ALL ZONES ARE PURGED 9 ADJUST SYSTEM TO DESIRED OPERATING FILL PRESSURE IF REQUIRED 10 MOVE ALL ZV TO CLOSED AUTOMATIC POSITION Figure 3 3 ...

Page 4: ...or the double insulation symbol square within a square In a double insulated appliance two systems of insulation are provided instead of grounding No grounding means is provided on a double insulated appliance nor should a means for grounding be added Servicing a double insulated appliance requires extreme care and knowledge of the system and should be done by qualified service personnel Replaceme...

Page 5: ...This is especially important when installing the circu lator in the off season An orange LED will illuminate when the 007e 2 is powered on 6 Green Mode Responsive technology actively monitors system condi tions and automatically adjusts to optimize power consumption In this mode the LED changes to green CAUTION Never run the circulator dry or permanent damage may result ATTENTION Ne laissez jamais...

Page 6: ... LED indicates the circulator is locked or sticking Disconnect and connect power supply to start the automatic release process The circulator makes 100 attempts to restart process lasts approximately 15 minutes Every restart is signalled by a short white flash of LED light If the locking is not removed through the automatic release pr ocess after 100 attempts to restart the circulator it goes into...

Page 7: ...ws 5 per bag 0010 025 RP Integral Flow Check IFC 007 007 RP Flange gasket set Replacement Parts 2021 LIMITED WARRANTY STATEMENT Taco Inc will repair or replace without charge at the company s option any Taco High Efficiency circulator or circulator part which is proven defective under normal use within three 3 years from the date of manufacture In order to obtain service under this warranty it is ...

Page 8: ...of pipe or closed loop hydronic heating systems Not suitable for chilled water systems Taco circulator pumps are for indoor use only employer uniquement a l interieur Acceptable for use with water or maximum of 50 water glycol solution FEATURES ECM performance equivalent to Taco s legendary 007 circulator Use with Taco SmartPlug Instant Hot Water Control for hot water when you need it Multi color ...

Page 9: ... additives to systems using TACO equipment voids the warranty Consult factory for fluid compatibility ATTENTION L ajout de liquides à base de pétrole ou de certains additifs chimiques à des systèmes utilisant un équipement TACO annule la garantie Consultez le fabricant pour con naître la compatibilité de liquides CAUTION Installations at elevations over 5000 feet must have higher fill pressure of ...

Page 10: ...n system Open all isolation valves Once system is filled close the fixture at the highest point in the system Close isolation valve on pump discharge Option No 1 location Open drain valve on pump discharge until all remaining air has been purged Close drain valve Operate pump until all remaining air is purged from bearing chamber 2 3 4 5 6 7 ...

Page 11: ...Open FF valve Open V2 PV4 to purge last zone First Zone 3 Close FF Valve Close V2 PV4 Repeat steps 1 to 6 for each additional zone purge zone 1 last Open V1 when all zones are purged Adjust system to desired operating fill pressure if required 2 3 4 5 6 7 8 9 V1 V2 V3 Shut off Isolation Valve P Taco circulator with IFC installed FF Fast Fill Boiler Feed Valve PV4 Purge Valve ...

Page 12: ... the circulator See page 3 for recommended air purging steps CAUTION To reduce the possibility of noise transmission be sure to add vibration dampeners to piping when mounting circulator to wall or floor joists ATTENTION Pour réduire la possibilité de transmission de bruit veillez à ajouter des amortisseurs de vibration à la tuyauterie lors du montage du circulateur sur des chevêtres de mur ou de ...

Page 13: ...e CAUTION Never run the circulator dry or permanent damage may result ATTENTION Ne laissez jamais le circulateur tourner à sec des dommages permanents peuvent en résulter CAUTION Do not attempt to remove LED panel from circulator Serious damage to circulator electronics may result ATTENTION N essayez pas de retirer le panneau de LED du circulateur Des dommages sérieux à l électronique du circulate...

Page 14: ... 7 Orange LED Green LED Proportional Pressure Mode 007e Performance Curves Normal Mode Green Mode 007e Performance Curves ...

Page 15: ...k for impeller rotation 7 If the circulator still doesn t run it will need to be replaced FAULTS CONTROL PANEL CAUSES REMEDIES The circulator is noisy LED on Suction pressure is insufficient cavitation Increase the system suction pressure within the permissible range LED on Presence of foreign bodies in the impeller Disassemble the motor and clean the impeller Loud noises of water circulation Flas...

Page 16: ...SOLDSEPARATELY Part Description UFS 050S 1 2 Sweat tailpiece set UFS 050T 1 2 NPT tailpiece set UFS 050P 1 2 Press tailpiece set UFS 075S 3 4 Sweat tailpiece set UFS 075T 3 4 NPT tailpiece set UFS 075P 3 4 Press tailpiece set Lead FreeShut Off FLANGE SOLDSEPARATELY Part Description SFL 050T 1 2 NPT SFL 050S 1 2 Sweat SFL 075T 3 4 NPT SFL 075S 3 4 Sweat SFL 100T 1 NPT SFL 100S 1 Sweat SFL 125T 1 1 ...

Page 17: ... 10 NOTES ...

Page 18: ... 11 NOTES ...

Page 19: ...consequential damages so these limitations or exclusions may not apply to you LIMITED WARRANTY STATEMENT Taco Inc will repair or replace without charge at the company s option any Taco product which is proven defective under normal use within three 3 years from the date code In order to obtain service under this warranty it is the responsibility of the purchaser to promptly notify the local Taco s...

Reviews: