7. Storage

7.1. General information

Follow the storage instructions in this manual to optimize the lifespan of TAB Li-Ion 
LiFePO4 battery during storage. If these instructions are not followed and TAB Li-Ion 
LiFePO4 battery has no charge remaining when it is checked, consider it to be 
damaged. Do not attempt to recharge or use it. Replace it with a new LiFePO4 
battery.
See chapter 2.4 for storage temperature conditions.
The self-discharge of TAB Li-Ion LiFePO4 battery is 1-2% per month.

 

 

Warning! 

 

1. Charge TAB Li-Ion LiFePO4 battery to > 80% of its capacity before storage.

  2. Disconnect TAB Li-Ion LiFePO4 battery from all loads and, if present, the  

 

  charging device.
  3. Place the terminal covers over TAB Li-Ion LiFePO4 battery’s terminals during 
 storage.
  4. Charge TAB Li-Ion LiFePO4 battery to > 80% of its capacity every 100 days. 
  After charging set the LiFePO4 battery in storage mode again.

8. Disposal and Recycling

8.1. General Information

Always discharge TAB Li-Ion LiFePO4 battery before disposal. Use electrical tape or 
other approved covering over the battery connection points to prevent short circuits. 
Battery recycling is encouraged. Dispose of the battery in accordance with local, 
state and federal laws and regulations. Batteries may be returned to the 
manufacturer.

USA & Canada:

Lithium Iron Phosphate batteries are subject to disposal and recycling regulations 
that vary by country and region. Always check and follow your applicable regulations 
before disposing of any battery. Contact Rechargeable Battery Recycling Corporation 
(www.rbrc.org) for U.S.A. and Canada, or your local battery recycling organization.

EC

Waste must be disposed of in accordance with relevant EC Directives and national, 
regional and local environmental control regulations. For disposal within the EC, 
the appropriate code according to the European Waste Catalogue (EWC) should be 
used.

18

Summary of Contents for LiFePO4

Page 1: ...www tab si TAB LI ION BATTERIES Lithium Iron Phosphate Batteries 6 4V 12 8V 25 6V USER MANUAL...

Page 2: ......

Page 3: ...In this manual our Lithium batteries as described above will be referred to as Sealed Lead Acid Replacement Batteries This manual is meant for the installer and the user of the LiFePO4 batteries Only...

Page 4: ...1 4 3 1 Location of the LiFePO4 battery 11 4 4 Connection Cables and 11 4 5 Connecting a Charger to the LiFePO4 Battery 12 4 6 Connecting Batteries in Parallel to a Charger Device 12 4 7 DC Load Conne...

Page 5: ...A period of use from fully charged to fully discharged and fully recharged again Endurance Life cycle The products maximum lifespan achieved by following the guidelines presented in this manual LiFePO...

Page 6: ...d Charge Voltage 7 3 VDC 0 2 V 14 6 VDC 0 2 V 29 2 VDC 0 2 V Cycle Life 1C 100 DOD 2000 cycles Clever 4000 cycles Premium 2000 cycles Clever 4000 cycles Premium 2000 cycles Clever 4000 cycles Premium...

Page 7: ...M6 HD 12 75 C 12 8 75 960 260 168 210 8 8 M6 HD 12 80 C 12 8 80 1024 260 168 210 9 2 M6 HD 12 100 C 12 8 100 1280 330 173 212 11 6 M8 HD 12 100L C 12 8 100 1280 335 175 195 11 6 M8 HD 12 120 C 12 8 12...

Page 8: ...32 260 168 210 8 1 M6 HD 12 75 P 12 8 75 960 260 168 210 8 8 M6 HD 12 80 P 12 8 80 1024 260 168 210 9 2 M6 HD 12 100 P 12 8 100 1280 330 173 212 11 6 M8 HD 12 100S P 12 8 100 1280 305 168 210 11 6 M8...

Page 9: ...placed in an enclosed environment without air circulation it is advised to provide 2 ventilation holes of 100 mm x 100 mm each to prevent heat built up 2 4 Product Lay out and Connections Recommended...

Page 10: ...area with copious amounts of water and seek medical advice Use battery charger devices that are capable to charge TAB LiFePO4 battery Observe the plus and minus marks on TAB LiFePO4 battery and equip...

Page 11: ...reseller or TAB d d Do not install or use TAB LiFePO4 battery if it is damaged 4 3 Preparing the Battery for Use Warning Always remain within the limits indicated in chapter 2 during the use of TAB L...

Page 12: ...charger to the battery 4 6 Connecting Batteries in Parallel to a Charger Device The max number of batteries in parallel is 20pcs and the max number of batteries in series is 4pcs To divide the current...

Page 13: ...charge However we recommend to install a bi stable latch relay which should be installed between the battery and the entire DC load or inverter as an extra security Ask your dealer or supplier for the...

Page 14: ...iFePO4 battery use a TAB d d charger or acharger approved by TAB d d 1 Connect the charger to the battery as described in paragraph 4 6 2 Charge TAB LiFePO4 battery in case of an empty shutdown or if...

Page 15: ...to the end of charge voltage Ubulk If UBulk is reached the charger will automatically switch to absorption phase The maximum charge current Imax for TAB d d batteries is 1C however for endurance cycl...

Page 16: ...es 10 minutes 1 hour Table 3 Absorption Phase Float phase In this phase the charge voltage is set to UFloat Float Phase Parameter Typical Min Max UFloat 13 8V DC 13 6V DC 14V DC Table 4 Float Phase Di...

Page 17: ...kage or damage of any other kind If damage to TAB Li Ion battery is found it must be replaced by a professional Do not attempt to charge or use a damaged TAB Li Ion battery Do not touch the liquid fro...

Page 18: ...rging set the LiFePO4 battery in storage mode again 8 Disposal and Recycling 8 1 General Information Always discharge TAB Li Ion LiFePO4 battery before disposal Use electrical tape or other approved c...

Page 19: ...d at its option upon having received those products returned by the customer has the option to either repair or replace such products by new products or to refund the invoice value exclusive of any di...

Page 20: ...pressly stated by TAB Li Ion in writing 9 7 Any liability to the customer in any case ceases to apply in the event that the customer fails to notify TAB d d of the existence of the defect within ten 1...

Page 21: ...TAB Tovarna Akumulatorskih Baterij d d Polena 6 SI 2392 Mezica Slovenia Tel 386 2 87 02 300 Web www tab si E mail info tab si P U R E E N E R G Y M A X I M U M P O W E R...

Reviews: