2.5. Operation Modes

Discharge mode

When the LiFePO4 battery voltage is below 2.5 V/Cell.

Deep discharge mode

For example, with 12V battery, when the LiFePO4 voltage is below 6 V. The LiFePO4  
battery is not usable anymore, and cannot be repaired, only recycled. Make sure the  
batteries are not deeper discharged than 10 VDC.

3. Safety Guidelines and Measures

3.1. General

• Do not short-circuit TAB LiFePO4 battery.
• Treat TAB LiFePO4 battery as described in this manual.
• Do not dismantle, crush, puncture, open or shred TAB LiFePO4 battery.

• Do not expose TAB LiFePO4 battery to heat or fire. Avoid exposure to direct sunlight.

• Do not remove TAB LiFePO4 battery from its original packaging until required for    
  use.
• In the event of TAB LiFePO4 battery leaking, do not allow the liquid to come in 
  contact with the skin or eyes. If contact has been made, wash the affected area with       
  copious amounts of water and seek medical advice.
• Use battery charger devices that are capable to charge TAB LiFePO4 battery.
• Observe the plus (+) and minus (–) marks on TAB LiFePO4 battery and equipment  
  and ensure correct use.
• Do not use any battery which is not designed for use with TAB LiFePO4 battery.
• Do not mix batteries of different manufacture, capacity, size or type within a device.
• Keep TAB LiFePO4 battery clean and dry.
• Secondary batteries need to be charged before use. Always use the correct charger 
  and refer this manual for proper charging instructions.
• Do not leave TAB LiFePO4 battery on continuous charge when not in use.
• After extended periods of storage, it may be necessary to charge and discharge TAB 
  LiFePO4 battery several times to obtain maximum performance.
• Retain the original product documentation for future reference.

 Warning!

 Keep the battery away from water, dust and contamination.

 Warning!

 Do not crush or puncture the battery.

 Warning!

 Never touch the battery contacts or allow (conductive) objects to touch

  the contacts.

10

Summary of Contents for LiFePO4

Page 1: ...www tab si TAB LI ION BATTERIES Lithium Iron Phosphate Batteries 6 4V 12 8V 25 6V USER MANUAL...

Page 2: ......

Page 3: ...In this manual our Lithium batteries as described above will be referred to as Sealed Lead Acid Replacement Batteries This manual is meant for the installer and the user of the LiFePO4 batteries Only...

Page 4: ...1 4 3 1 Location of the LiFePO4 battery 11 4 4 Connection Cables and 11 4 5 Connecting a Charger to the LiFePO4 Battery 12 4 6 Connecting Batteries in Parallel to a Charger Device 12 4 7 DC Load Conne...

Page 5: ...A period of use from fully charged to fully discharged and fully recharged again Endurance Life cycle The products maximum lifespan achieved by following the guidelines presented in this manual LiFePO...

Page 6: ...d Charge Voltage 7 3 VDC 0 2 V 14 6 VDC 0 2 V 29 2 VDC 0 2 V Cycle Life 1C 100 DOD 2000 cycles Clever 4000 cycles Premium 2000 cycles Clever 4000 cycles Premium 2000 cycles Clever 4000 cycles Premium...

Page 7: ...M6 HD 12 75 C 12 8 75 960 260 168 210 8 8 M6 HD 12 80 C 12 8 80 1024 260 168 210 9 2 M6 HD 12 100 C 12 8 100 1280 330 173 212 11 6 M8 HD 12 100L C 12 8 100 1280 335 175 195 11 6 M8 HD 12 120 C 12 8 12...

Page 8: ...32 260 168 210 8 1 M6 HD 12 75 P 12 8 75 960 260 168 210 8 8 M6 HD 12 80 P 12 8 80 1024 260 168 210 9 2 M6 HD 12 100 P 12 8 100 1280 330 173 212 11 6 M8 HD 12 100S P 12 8 100 1280 305 168 210 11 6 M8...

Page 9: ...placed in an enclosed environment without air circulation it is advised to provide 2 ventilation holes of 100 mm x 100 mm each to prevent heat built up 2 4 Product Lay out and Connections Recommended...

Page 10: ...area with copious amounts of water and seek medical advice Use battery charger devices that are capable to charge TAB LiFePO4 battery Observe the plus and minus marks on TAB LiFePO4 battery and equip...

Page 11: ...reseller or TAB d d Do not install or use TAB LiFePO4 battery if it is damaged 4 3 Preparing the Battery for Use Warning Always remain within the limits indicated in chapter 2 during the use of TAB L...

Page 12: ...charger to the battery 4 6 Connecting Batteries in Parallel to a Charger Device The max number of batteries in parallel is 20pcs and the max number of batteries in series is 4pcs To divide the current...

Page 13: ...charge However we recommend to install a bi stable latch relay which should be installed between the battery and the entire DC load or inverter as an extra security Ask your dealer or supplier for the...

Page 14: ...iFePO4 battery use a TAB d d charger or acharger approved by TAB d d 1 Connect the charger to the battery as described in paragraph 4 6 2 Charge TAB LiFePO4 battery in case of an empty shutdown or if...

Page 15: ...to the end of charge voltage Ubulk If UBulk is reached the charger will automatically switch to absorption phase The maximum charge current Imax for TAB d d batteries is 1C however for endurance cycl...

Page 16: ...es 10 minutes 1 hour Table 3 Absorption Phase Float phase In this phase the charge voltage is set to UFloat Float Phase Parameter Typical Min Max UFloat 13 8V DC 13 6V DC 14V DC Table 4 Float Phase Di...

Page 17: ...kage or damage of any other kind If damage to TAB Li Ion battery is found it must be replaced by a professional Do not attempt to charge or use a damaged TAB Li Ion battery Do not touch the liquid fro...

Page 18: ...rging set the LiFePO4 battery in storage mode again 8 Disposal and Recycling 8 1 General Information Always discharge TAB Li Ion LiFePO4 battery before disposal Use electrical tape or other approved c...