54
Calibration
Although calibration of the Astro ST2 is not necessity, it is recommended periodically for
preventative maintenance, and after any change to the software configuration of the unit.
To carry out this calibration you need two adjustment papers for the Astro ST2.
(Order number: 28600035 - Calibration paper set Astro ST2).
Procedure:
1.
Push button 3 times, the rear diagnostic LED will rapidly flash orange to show the unit is
in calibration mode.
2.
Insert the white calibration paper. It should be presented in the center of the note path
and square to the direction of travel.
The currency validator will draw-in the paper all the way into the cassette; hold it
momentarily before returning it in several short steps.
3.
Remove the white calibration paper and insert the black calibration paper.
The unit will draw-in the paper and return it immediately in one smooth action.
4.
Calibration is complete.
If calibration has not been successful, the diagnostic LED will repeatedly flash a four-color
error code until the push button is pressed to cancel.
Summary of Contents for MAXFIRE HD+
Page 1: ...MAXFIRE HD Manual English...
Page 12: ...Manual MaxFire HD _en COMPLETE docx BG 12...
Page 17: ...Manual MaxFire HD _en COMPLETE docx BG 17 Menu Hardware Settings...
Page 56: ...Manual MaxFire HD _en COMPLETE docx BG 56 Wiring Diagram Main Harness...
Page 57: ...Manual MaxFire HD _en COMPLETE docx BG 57 Block Diagram Power Cables...
Page 58: ...Manual MaxFire HD _en COMPLETE docx BG 58 Exploded Assembly Drawings Main Frame Display Front...
Page 59: ...Manual MaxFire HD _en COMPLETE docx BG 59 Assembly Cabinet...
Page 60: ...Manual MaxFire HD _en COMPLETE docx BG 60...
Page 61: ...Manual MaxFire HD _en COMPLETE docx BG 61 EC Declaration of Conformity...
Page 71: ...Manual MaxFire HD _en COMPLETE docx BG 71 Notes...