GLOSSARY

STAND BY 

The gate is completely closed and the stop, the external photocells, the internal photocells and the
opening limit switch are not activated. The control board is ready to start a working cycle. In this state the 
flashing lamp is off. 

OPENING 

The gate is opening and the flashing lamp blinks quickly (0.3 seconds ON and 0.2 seconds OFF).

PAUSE

When the opening is finished the motor is stopped and the flashing lamp is on. 
After auto-close time has expired (

F0

) the gate starts closing. 

CLOSING 

The gate is closing and the flashing lamp blinks slowly (0.6 seconds ON and 0.4 seconds OFF).

STOP

OPENING 

The gate has been stopped while it was opening. A new start command begins the closing phase. 
In this state the flashing lamp is off.

STOP

CLOSING 

The gate has been stopped while it was closing. A new start command begins the opening phase.
In this state the flashing lamp is off.

TYPE OF

INPUTS 

The input can be an external input or a remote key.
The external inputs are all objects that can be wired to the terminal block of the control board. Each pin of 
the terminal block is associated to a specific function. The safety functions match the normally closed 
contacts. The other functions match the normally open contacts. The safety functions are: stop, internal 
photocell, external photocell, closing limit switch and opening limit switch. While the others are: start (or fast 
closure start) and pedestrian start. The pins of the terminal block can be enabled or disabled by programming 
parameters 

E1

E2

E3

E4

E5

E6

,  

E7

. The remote key inputs are all functions linked to a remote 

key. They are: start, stop, pedestrian start and fast closure start. The control board doesn't distinguish 
between the type of inputs but only between the functions. 

INPUT IS

ACTIVATED 

An input is activated when its state changes from the standard state. For example a photocell is activated 
when the beam from the transmitter to the receiver is broken, while a generic switch, push-button or remote 
key is activated when it is pushed down. All these actions are recognized by the control board which shows 
these changes on the display. When more inputs are activated at the same time the control board will show 
only the most critical input. The order from the most critical to the least critical input is:

St

 =

stop

tC

 =

external 
photocell 

tA

 =

internal 
photocell

Go

 = 

start or fast 
closure start

PE

 =

pedestrian start

FC

 =

closing limit 
switch

FA

 =

opening limit 
switch

START

COMMANDS

The start commands are: start, pedestrian start and fast closure start. They are able to start a working cycle. 
The function of start commands depend on 

F5

 and 

F6

 parameters programming. 

To know more see 

F5

 and 

F6

 description. 

To know how the fast closure start command works see 

F7

 description.

To know how the start command works see 

Standard Working Cycle

To know how the pedestrian start command works see 

Pedestrian Working Cycle

.

SAFETY

COMMANDS

The safety commands are: stop, internal photocell and external photocell. The stop commands always stop 
the gate. Instead the function of the photocells depend on 

F8

 programming. 

To know more see 

F8

 description.

STANDARD

WORKING

CYCLE

A start command has been received when the control board was in stand by state.
The motor works for a total time of 

A1

 plus 

A2

 seconds during the opening and the closing. When a 

standard working cycle is in progress, the pedestrian start commands are considered as a start. The working 
cycle is finished when the control board returns to stand by state. This functionality can be handled by 
parameters programming. 

PEDESTRIAN

WORKING

CYCLE

A pedestrian start command has been received when the control board was in stand by state.
The motor works for a total time of 

F1

 seconds during the opening and closing. The slowdown phase is 

skipped during the opening and executed during the closing. The slowdown time is automatically managed by
the control board during a pedestrian working cycle. When a pedestrian working cycle is in progress, the start 
commands are considered as a pedestrian start. The working cycle is finished when the control board returns 
to stand by state.

www.tecnoautomazione.com

                                                                                                                                                                               Pag. 6 / 17

Summary of Contents for T011S

Page 1: ...3DOLDQR 5 WDO RFDOLWj HUYLQDUD 7HO D 9LD 9LFLQDOH VQF LQIR WHFQRDXWRPD LRQH FRP ZZZ WHFQRDXWRPDWLRQ FRP 7 7HFQR XWRPD LRQH V U O A K M 7 W M J 7 M K A b M J 7HO HTSYWTQ ZSNY KTW XQNINSL LFYJX 86 5 0 1...

Page 2: ......

Page 3: ...E 6 A6 SLOWDOWN FORCE 6 A7 STANDARD OBSTACLE DETECTION THRESHOLD 6 A8 SLOWDOWN OBSTACLE DETECTION THRESHOLD 6 SENSOR OPERATING MODE 7 FUNCTIONS 8 F0 AUTO CLOSE TIME 8 F1 PEDESTRIAN WORKING TIME 8 F2 C...

Page 4: ...NTS A Button A B Button B C Button C D Button D F1 250 VAC power fuse 5A F4 Resettable fuse 24V 1 6A F5 Resettable fuse 24V 0 6A A B C Ground terminals CN Primary varistor V1 Secondary varistor V2 Ter...

Page 5: ...block input 7 is activated Parameter E7 is set to PE PEDESTRIAN A remote stored as r3 PEDESTRIAN START function is transmitting Eo DOMUS NO Terminal blocks inputs 1 2 3 4 or 7 are activated Parameters...

Page 6: ...INSTALLATION www tecnoautomazione com Pag 4 17 RADIO BODY BODY RADIO BASE LIGTHS max 10W 24V COVER COVER ANTENNA COVER ANTENNA BASE Screws and stops not included 3 5mm x 13mm 3 5mm x 13mm 4 mm x 35mm...

Page 7: ...VAC E1 DISABLED no START Go OPEN oP CLOSE CL E2 DISABLED no STOP 5t E5 DISABLED no CLOSING LIMIT SWITCH N C FC CLOSING LIMIT SWITCH N A LC E6 DISABLED no OPENING LIMIT SWITCH N C FA OPENING LIMIT SWIT...

Page 8: ...r remote key is activated when it is pushed down All these actions are recognized by the control board which shows these changes on the display When more inputs are activated at the same time the cont...

Page 9: ...dard working time A1 If the control board detects a motor stress higher than A7 it means that there is an obstacle in the way of the gate The control board will make a decision in accordance with its...

Page 10: ...detection mode If the opening limit switch input is not installed E6 no and the opening is in progress The sensor works in obstacle detection mode during the standard working time A1 During the slowd...

Page 11: ...t opening once the external photocells have been activated the gate will start to close after 5 seconds For safety reasons it is advisable to enable this function only when two pairs of external photo...

Page 12: ...ors are detected the motors can be started Vice versa the motors cannot start and the control board display shows 1t MOTORS TEST t2 t2 SI ENABLED t2 no DISABLED Before each gate movement the motor is...

Page 13: ...The motor works for a total time of A1 plus A2 seconds during the opening and the closing r2 STOP The stop function stops the gate r3 PEDESTRIAN The pedestrian function begins a Pedestrian Working Cyc...

Page 14: ...al photocells does not have any effect N C SAFETY DEF INTERNAL PHOTOCELL NC Go The START function begins a STANDARD WORKING CYCLE The gate opens for A1 plus A2 slowdown seconds stays open for F0 secon...

Page 15: ...To go to F0 press any start input F0 The pause time is being programmed F0 The gate is stopped The flashing lamp is on After 1 5 seconds the control board display shows the counting time To finish th...

Page 16: ...ivity The following tables show the values of A5 A6 A7 A8 B8 for electric gate motor models M2 500 M2 800 and M2 1500 www tecnoautomazione com Pag 14 17 STANDARD MODE SENSOR CALIBRATION ELECTRIC GATE...

Page 17: ...hts can be controlled by terminal block input remote key and or gate status The most useful functions are ON ON OFF ON from 0 to 99 Seconds Minutes Hours DOMUS controls up to 3 lights The lights can b...

Page 18: ...NOTES www tecnoautomazione com Pag 16 17...

Page 19: ......

Page 20: ...86 5 0 18 a 1 VHMS A 7b MJ 0 1 7 3DOLDQR 5 WDO RFDOLWj HUYLQDUD 7HO D 9LD 9LFLQDOH VQF LQIR WHFQRDXWRPD LRQH FRP ZZZ WHFQRDXWRPDWLRQ FRP 7 7HFQR XWRPD LRQH V U O A K M 7 W M J 7 M K A b M J 7HO J XMTU...

Reviews: