How to Perform a Fault Location Test
•
Power on the Power Prowler.
•
Connect the Dual Banana to BNC Female adapter and alligator clip set to the
Power Prowler, then connect the cable under test.
•
Select the Fault location icon using the right arrow button, then press the
enter button or press the ruler icon soft key
.
•
Use the left or right arrow buttons to scroll to the cable type to be tested.
»
To edit an existing cable VOP, use the up and down arrows to change
the VOP. Once the desired VOP is displayed, press the save soft key.
To cancel, press the cancel soft key
, or use the back arrow soft
key
to return to the test screen without saving the adjusted
VOP. To restore the default VOP, press the default soft key.
»
If the cable type is not listed, but the VOP is known, press the star soft
key
to add a custom cable type.
»
If the VOP is not known, connect to a known length of the same cable
type. Select the CAL soft key
and adjust the length by pressing
the up/down arrows or press the soft keys under +50ft and -50ft
until the length of the cable is displayed. Press the test button
to
discover the VOP or press the cancel soft key to cancel.