TPF / TFB Series Floor Scale Service Manual
- 1 -
1. BASIC INFORMATION
1.1 Documentation
These installation instructions contain all data necessary for placing and
commissioning the floor scales.
1.2 Proper Use
This scale is intended to determine the weighing value of material to be weighed.
It is intended to be used as a “non-automatic balance”.
i.e. the goods to be weighed is manually and carefully placed in the center of the
weighing plate, As soon as stable weighing value is reached the weighing value
can be read.
1.3 Improper Use
Do not leave permanent load on the floor scales.
Do not load the platform, if there is any evidence of damage to the platform
or supporting structure.
Ch
anges to the weighing system’s design are not permitted. This may lead
to incorrect weighing results, safety-related faults and destruction of the
balance.
1.4 Monitoring
In the frame work of quality assurance the measuring
–related properties of the
weighing system and, if applicable test weight, must be checked regularly.
1.5 General
Two types of floor scales are available, mild steel and stainless steel.
The TPF floor scale sizes range from 1190x840mm. TFB sizes range from
1200x170x100m
Easy accessible stainless steel junction box.
Four Load cells
Adjusting leveling foot
Overload up to 150%
All models have threated holes in the decks for attaching eyebolts to
facilitate installation and cleaning