background image

IHB++ Series Technical Manual 

                                                                                                                                  

- 7 - 

 
Installation 

 

 

 

   

 

 

  Place the scale on a table..  

  Connect the adaptor pin in to the scale adaptor jack. Adaptor jack is locating, 

rear side of the scale. 

  Adaptor connects into your AC power socket. Pluggable equipment must 

be installed near an easily accessible socket outlet with a protective 

ground/ earth contact. 

  Turn on the On/Off key. If you want to turn off, press the key again. 

  Display will be show the version number and will be starting self checking. 

  After self checking, display will be come to normal weighing mode.  

 

Warm-up time of 15 minutes stabilizes the measured values after 

switching on. 

  Calibrate with exact calibration weights, minimum 1/3 of the scale capacity 

want to use for calibration. For calibration, see details in parameter.  

 

Then you can start your operation 

 

Pan 

Adjustable foot 

RS-232 

USB 

Adaptor Jack 

Summary of Contents for IHB++ -300

Page 1: ...IHB Series Precision Balance REV M1 JUne 2014 ...

Page 2: ...IHB Series Technical Manual II ...

Page 3: ... Power ON OFF 10 6 2 Zero 10 6 3 Tare 10 6 4 Weighing Unit 10 6 5 Percent Weighing 11 6 6 Parts Counting 11 6 7 Accumulation 12 7 PARAMETER 13 8 CALIBRATION 15 8 1 Linear Calibration 15 8 2 Normal Calibration 16 8 3 Manual Calibration by built in weight 16 8 4 Check internal Counts 16 9 RS232 OUTPUT 17 9 1 Specifications 17 9 2 Continuously output protocol 17 9 3 Print Format 17 ...

Page 4: ...to or destruction of the equipment The weighing scale is a precision electronic instrument handle it carefully Do not install the scale in direct sunlight Verify the local voltage and receptacle type are correct for the scale Only use original adaptor other could cause damage to the scale Pluggable equipment must be installed near an easily accessible socket outlet Avoid unstable power sources Do ...

Page 5: ...st and versatile series of general purpose balances with counting weighing functions and accumulation 16 5 mm LCD with white LED back light display Battery provide up to 40 hours of continues use with out backlight Capacity 300g and 3000g All units include automatic zero tracking tare and an accumulation facility that allows the count to be stored and recalled as an accumulated total ...

Page 6: ...Model IHB 300 IHB 3000 Maximum Capacity 300g 3000g Readability 0 001g 0 01g Resolution 1 300 000 1 300 000 Tare range 299 999g 2999 99g Minimum Capacity 0 02g 0 2g Linearity 0 003g 0 01g Platter Φ80mm Φ120mm Wind shield Yes Yes Units of Measure g ct lb oz d gn ozt dwt mom tlT tlh tlj t bt n ...

Page 7: ...l 12V 500mA or built in rechargeable battery 6V 1 2Ah Calibration Automatic External ADC Σ Δ Display 16 5 mm high 6 digits LCD with auto backlight and loading bar graph Balance Housing ABS Plastic Stainless Steel platform Pan Size Φ80mm Φ120mm Overall Dimensions wxdxh 220mm x 340mm x 321mm Other Features and Specs accuracy enhancement for parts counting and percentage weight function ...

Page 8: ...n you change the location Charging Battery To charge the battery insert the adaptor pin to jack jack is locating rear side of the scale Adaptor simply plug into the mains power The scale no needs to be turned on The battery should be charged for 12 hours for full capacity Left side of the display there is an LED to indicate the status of battery charging When the scale is plugged into the mains po...

Page 9: ...earth contact Turn on the On Off key If you want to turn off press the key again Display will be show the version number and will be starting self checking After self checking display will be come to normal weighing mode Warm up time of 15 minutes stabilizes the measured values after switching on Calibrate with exact calibration weights minimum 1 3 of the scale capacity want to use for calibration...

Page 10: ...ical Manual 8 5 DESCRIPTION Key Board Turns the scale power On Off Sets display to Zero Subtracts weight of container Set percentage weighing function Set to counting mode Set to weighing units Set to print the results ...

Page 11: ...dicator for Tare display Indicator for weighing capacity graph Indicator for Net weight Indicator for Display stability Indicator for piece counting Indicator for units Indicator for Percent weighing Indicator for Charging status of battery Voltage has dropped Low Voltage Fully Charged ...

Page 12: ... of your balance to zero any time by pressing key and therefore ensure that the weighing starts at zero 6 3 Tare The weight of any container can be tared by pressing button so that with subsequent weighing the net weight of the object being weighed is always displayed Load weight on the pan Press key Zero is displayed and tare is subtracted Remove weight from the platform Tared weight is displayed...

Page 13: ...100 The weighing may be amended on the basis of greater numbers of samples improves the accuracy of percentage large quantities 6 6 Parts Counting Parts Counting Press key enter the parts counting mode and select the counting options by pressing Display will be shown sp 10 For 10 pieces sP 20 For 20 pieces sP 50 For 50 pieces sP 100 For 100 pieces sP 200 For 200 pieces Select the counting option a...

Page 14: ...ey when displayed STABLE indication Display will be show then will be show the total saved value These displays will be shown only three seconds If the optional RS 232 interface is installed the weight data will be send to printer Remove the weight from the pan When display get zero and stable then place the second weight It can continue until the memory gets fully 6 7 1 Memory Recall To recall th...

Page 15: ... can escape from the menu to weighing mode Menu Sub Menu Description F1 unt ct lb oz d gn ozt dwt mom tl T tlj tlh t bt n To select weighing unit on off F 2 bl El au To set back light automatic on El on To set back light always on El off To set back light always off F3 com S 23 2 S usb Select first RS 232 or USB P prt By pressing Print key weighing value will be added to the memory and print the p...

Page 16: ...c Acc on Accumulation function enable Acc of Accumulation function disable tech pin Enter the password P 1 lin Linear Calibration P 2 Cal Normal Calibration P 3 cnt xxxx This display will show XXXXX for indicating the internal counts P 4 a 2n A2 off To set to disable auto zero function A2 0 5d To select the auto zero ranges A2 1d A2 2d As 4d P 5 gra XXXXX To set local gravity P6 cap 120g 10000 g T...

Page 17: ...on the pan After stable and zero indicator on display will be show Load 2 Add again the second calibration mass weight on the pan After stable and zero indicator on display will be show Load 3 Add again the third calibration mass weight on the pan After stable and zero indicator on display will be show Load 4 Add again the fourth calibration mass weight on the pan Note Calibration mass weight shou...

Page 18: ...ring the linear calibration steps LOAD 4 to LOAD 1 mass weights want to reduce from the pan Don t remove all mass weights for the next step 8 2 Normal calibration p2 cal Press key to enter calibration display will be show kg or lb press key to select the calibration unit kilograms or pounds press key display will be show unLoad Remove all the weight from the platform When scale get stable display ...

Page 19: ...s the display will be show XXXXX Press key to escape from the menu 9 RS232 OUTPUT 9 1 Specifications RS 232 output of weighing data ASCII code 600 9600 Baud 8 data bits No Parity 9 2 Continuously output protocol HEADER1 ST STABLE US UNSTABLE HEADER2 NT NET GS GROSS ...

Page 20: ... 50 OS 2130D TP Weighing 2013 07 05 12 00 S NO 1 WEIGHT 200 000g NO 1 WEIGHT 200 000g Counting 2013 07 05 12 00 COUNT 250 pcs UNIT WT 0 99998 g WEIGHT 249 998 g COUNT 250 pcs UNIT WT 0 99998 g WEIGHT 249 998 g Percent 2013 07 05 12 00 PERCENT 100 00 PERCENT 100 00 ...