Format
TIMER,Upload time#
TIMER,30#
Description
1 time range: 10~60 seconds;
2 the default is 10 seconds to upload!
3 timing boot and deep sleep mode has been
dormant, upload interval is invalid.
Feedback
SET TIMER OK!
(7) SLEEEP
Command
Parameter
Sample
Parameter
SLEEP,mode#
SLEEP,0#(Power saving mode)
SLEEP,1#(Intelligent sleep mode)
SLEEP,2# (Deep sleep mode)
Description
1 device factory default mode 1, intelligent sleep
mode.
2 Intelligent sleep mode, the device will turn off the
GPS when it is stationary for 3 minutes, and the
exercise can wake up the GPS
3. Deep sleep mode, device in completely dormant
state, is not affected by the movement and stillness,
only to send instructions WAKE# or center number
call to wake up, every time the wake-up time only
lasted 3 minutes, 3 minutes after equipment will again
to enter the deep sleep state.
4 In the power-saving mode, the device will enter the
dormant state when it is stationary for 3 minutes, turn
off GPS and GPRS, and wake up GPS and GPRS
during sports.
Feedback
Set OK, the model is: intelligent sleep mode!
(8) POWER
Command
parameter
Sample
POWER
POWER,time#
POWER,10#
POWER,102#
Description
1) POWER instructions are used to set the device
timer switch function.
2) after the instruction is sent, the three working modes
are closed, and the timing switch mode is executed.
3) from time to time to open the shutdown, the need
to remove the switch is pressed, to perform the
shutdown timer start function