1. Technical parameter

1. GSM

850/900/1800/1900MHz

2. GPRS

Class12,TCP/IP

3. Working Voltage

3.90V DC   

4. Working current

≈35mA (12vDC)

5. Working current

≈4mA (24vDC)

6. GPS locating time

Cold start

≈38s (Open sky) Hot start≈2s (Open 

sky)                                                                         
7. GPS Precision

10m

2D RM

8. Working temperature

-20

+70

9. Working humidity

20%

80%RH

10. Measurement

87 (L) × 54 (W) × 26 (H) m

2. Out look

3. Device status indicators

3.1.1 Blue LED (working status indicator)
After the device is turned on, the LED lights flashing (0.3 s/3 s).
3.2 Red LED (charge status indicator)
This LED light is not bright, the charge of this LED flashing (0.3 s /3 s), full 
of electricity, the LED light is always bright.
All  LEDs will  turn  off  after  3 minutes.  When  there  is a  new  call, the  LEDs  will 
relight and turn off 3 minutes later.

Summary of Contents for T2-1

Page 1: ...carefully before use the GPS Tracker so that you can install the device correctly and activate it quickly on the internet The outlook and true color are subject to the actual product Vehicle GPS Tracker User Manual Model T2 1 ...

Page 2: ... 9 Working humidity 20 80 RH 10 Measurement 87 L 54 W 26 H m 2 Out look 3 Device status indicators 3 1 1 Blue LED working status indicator After the device is turned on the LED lights flashing 0 3 s 3 s 3 2 Red LED charge status indicator This LED light is not bright the charge of this LED flashing 0 3 s 3 s full of electricity the LED light is always bright All LEDs will turn off after 3 minutes ...

Page 3: ...l card slot on the outside you can pop as follow Note don t install backwards the terminal GSM card If your GSM card need input PIN when power on please refer your phone s user manual and cancel it 5 Terminal operation status 5 1 Boot terminal insert SIM card while the anti tamper switch to play up automatically boot Blue light has a regular flashing 0 3 sec 3 sec it means that the equipment is wo...

Page 4: ... 6 7 Built in 3D accelerator distinguished between motion and stationary state intelligent power saving 6 8 Can be at any time to check the latitude and longitude of the text message 6 9 6800MA large battery power supply the use of more long term 6 10 Using AGPS program positioning time is more efficient 7 user instructions 1 CENTER Command Parameter Sample ADD CENTER A number CENTER A 13500135000...

Page 5: ... GMT E 8 2 GMT E 6 30 Description The default time zone on the terminal is the Beijing time zone E8 if need to change the time zone need to send the above instructions Range E W 0 12 Feedback SET GMT OK 5 VIBRATION Command Parameter Sample Format VIBRATION level alarming way 1 VIBRATION 2 3 2 VIBRATION 2 Description The sensitivity value of the vibration is from 1 to 5 1is the most sensitive and o...

Page 6: ...ed by the movement and stillness only to send instructions WAKE or center number call to wake up every time the wake up time only lasted 3 minutes 3 minutes after equipment will again to enter the deep sleep state 4 In the power saving mode the device will enter the dormant state when it is stationary for 3 minutes turn off GPS and GPRS and wake up GPS and GPRS during sports Feedback Set OK the mo...

Page 7: ...mal mode and timing mode 3 when the device is not in a dormant state the instruction is not valid Feedback WEAK OK 10 FCALM Command parameter Sample FCALM FCALM way FCALM 1 Telephone alarm Description 1 this instruction in order to set up the alarm after the alarm mode 2 1 telephone alert 2 short message alert 3 telephone short message alert 3 the default off state that is to prevent the alarm rep...

Page 8: ...ter Sample URL URL URL Description Check the location link of Google map Feedback Datetime 18 11 05 13 21 30 http maps google com maps q N22 540885 E113 9 5265 14 RESET Command Parameter Sample Format RESET RESET Description This instruction is used to restart the device Feedback RESET OK 15 FACTORY Command Parameter Sample Parameter FACTORY FACTORY Descriptio n This instruction is to restore the ...

Page 9: ... One monitoring time is 3 minutes If you need to continue monitoring please dial the device number again The monitoring state is turned on by default 8 2 Set to turn off the monitoring send SMS command to turn off the monitoring function 9 Charging reminder Equipment using the built in charging head and line charging cannot be used indiscriminately charging line charging because we have fast 17 ST...

Page 10: ...essages WAKE 12 Trouble shooting 12 1 The device is not online or offline on the web platform 12 1 1 First observe whether the terminal indicator is normal If you cannot observe it please dial the SIM card number of the terminal with your mobile phone and determine the status of the terminal according to the prompt tone If not connected indicating that the terminal temporarily cannot connect or th...

Page 11: ...erminal which may affect the signal 12 3 When GSM signal receiving abnormal please check if the SIM card installed correctly or the GSM signals may not reach your location such as the basement please drive to the open sky 1w 4 The red LED is not glow when power on Check the fuse of the power line If the fuse is fused please change the fuse with the seller and check the device about the inner malfu...

Page 12: ...maintenance and repair by disassembling the machine without authorization 3 Soak damage or burn circuit board 4 Installation use maintenance or improper storage 5 Housings lenses or internal damage to the antenna 6 IMEI number tearing or blurred 7 Warranty certificate inconsistent with the product model or has been modified 8 Damage caused by irresistible force Maintenance Card Maintenance unit DA...

Page 13: ...IMEI serviceman ...

Reviews: